Performance | Max. number of steps per revolution: | 8,192 |
Max. number of revolutions: | 1 |
Resolution power: | 8,192 x 1 |
Resolution: | 13 bit |
Error limits: | ± 0.05 ° |
Repeat accuracy: | 0.002 ° |
Measuring step deviation: | ± 0.01 ° |
Measuring step: | 0.01 ° |
Initialization time: | 50 ms 1) |
|
Mechanical data |
Mechanical interface: | Blind hollow shaft |
Shaft diameter: | 10 mm |
Start up torque: | 0.8 Ncm (20 °C) |
Operating torque: | 0.6 Ncm (20 °C) |
Maximum operating speed: | 6,000 /min 1) |
Moment of inertia of the rotor: | 40 gcm² |
Bearing lifetime: | 3.0 x 10^9 revolutions |
Max. angular acceleration: | 500,000 rad/s² |
Permissible movement axial static/dynamic: | ± 0.5 mm, ± 0.2 mm |
Permissible movement radial static/dynamic: | ± 0.3 mm, ± 0.1 mm |
Type of mounting shaft: | Blind hollow shaft |
|
Electrical data |
Power consumption: | 0.5 W (without load) |
Operating voltage range: | 4.5 V DC ... 32 V DC |
MTTFd: mean time to dangerous failure: | 250 a (EN ISO 13849-1) 1) |
Connection type: | Cable, 8-pin, universal, 5 m 2) |
Code type: | Gray |
Code sequence: | CW/CCW, parameter adjustable |
Reverse polarity protection: | 1 |
|
Interfaces |
Electrical interface: | SSI/Gray |
Interface signals: | Clock +, Clock -, Data +, Data- |
Clock frequency: | 2 MHz 1) |
SET (electronic adjustment): | H-active (L ≡ 0 - 1,5 V, H ≡ 2,0 - Us V) |
CW/CCW (counting sequence when turning): | L-active (L ≡ 0 - 1,5 V, H ≡ 2,0 - Us V) |
|
Ambient data |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) 1) |
Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529) |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Working temperature range: | -30 °C ... 100 °C |
Storage temperature range: | -40 °C ... 100 °C, without package |
Resistance to shocks: | 70 g, 6 ms (according to EN 60068-2-27) |
Resistance to vibration: | 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
|