Performance | Max. number of steps per revolution: | 360 |
Max. number of revolutions: | 1 |
Resolution power: | 360 x 1 |
Error limits: | 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) |
Repeat accuracy: | 0.005 ° |
Measuring step deviation: | 0.005 °, 0.016 ° |
Measuring step: | 360 ° /number of lines |
Initialization time: | 80 ms 1) |
|
Electrical data |
Operating voltage range: | 10 V DC ... 32 V DC |
Operating power consumption (no load): | 90 mA |
|
Interfaces |
Electrical interface: | Cable, 22-pin, axial, 1.5 m |
|
Ambient data |
EMC: | According to EN 61000-6-2 and EN 61000-6-3 1) |
Enclosure rating: | IP 66, according to IEC 60529
|
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Working temperature range: | -20 °C ... 85 °C |
Storage temperature range: | -40 °C ... 100 °C |
Resistance to shocks: | 50 g (according to EN 60068-2-27) |
Resistance to vibration: | 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
|