Functions-Sender | Beam coding: | |
Configuration method: | hard wired |
Extension connection: | |
Safe device communication via EFI/SDL: | - |
|
Functions-Receiver |
Restart interlock: | - |
External device monitoring: | |
Beam coding: | |
Muting with: | Flexi Classic, Flexi Soft |
Configuration method: | hard wired |
Extension connection: | |
Safe device communication via EFI/SDL: | - |
|
Technical Data-Sender |
Protective field height: | 1,800 mm |
Resolution: | 40 mm |
Scanning range from ... to: | 0 m ... 6 m |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 2 (IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) |
Category: | category 2 (EN ISO 13849) |
Test rate (internal test): | 13 /s (EN ISO 13849) |
Maximum demand rate: | 8 /min (EN ISO 13849) 1) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 2.2 * 1E-08 |
TM (Mission Time): | 20 a |
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | III |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 68-2-29) |
Weight: | 3.88 kg |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Maximum power consumption: | 6.2 W |
Wave length: | 950 nm |
Connection type: | plug M12 x 8 |
Connection type extension connection: | plug M12 x 8 |
Maximum connection cable cross-section: | 0.25 mm2 |
|
Technical Data-Receiver |
Protective field height: | 1,800 mm |
Resolution: | 40 mm |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 2 (IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) |
Category: | category 2 (EN ISO 13849) |
Test rate (internal test): | 13 /s (EN ISO 13849) |
Maximum demand rate: | 8 /min (EN ISO 13849) 1) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 2.2 * 1E-08 |
TM (Mission Time): | 20 a |
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | III |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 68-2-29) |
Weight: | 3.88 kg |
Response time: | 18 ms |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Maximum power consumption: | 8 W |
Maximum switching voltage: | min. VS - 2.25 V DC |
Maximum switching current: | 500 mA |
Wave length: | 950 nm |
Connection type: | plug M12 x 8 |
Connection type extension connection: | plug M12 x 8 |
Maximum connection cable cross-section: | 0.25 mm2 |
|