Select Store:
Select Currency:

Sick C20E-180304A22 (1018149)

Product Summary

Testable Lightgrid C2000 cascadable/RES Receiver C20E-180304A22 1800mm Protective Field Hight, 40mm resolution
Manufacturer: Sick
Manufacturer part number: 1018149
SKU: 148031
Weight(kg): 3.8000

Click here to check availability

Pricing - Condition Manufacturer New

£1,762.48 excl VAT
£1,674.36 excl VAT
Functions-Sender
Beam coding:
Configuration method:hard wired
Extension connection:
Safe device communication via EFI/SDL:-
Functions-Receiver
Restart interlock:-
External device monitoring:
Beam coding:
Muting with:Flexi Classic, Flexi Soft
Configuration method:hard wired
Extension connection:
Safe device communication via EFI/SDL:-
Technical Data-Sender
Protective field height:1,800 mm
Resolution:40 mm
Scanning range from ... to:0 m ... 6 m
Housing cross-section:48 mm x 40 mm
Type:Type 2 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (IEC 62061)
Category:category 2 (EN ISO 13849)
Test rate (internal test):13 /s (EN ISO 13849)
Maximum demand rate:8 /min (EN ISO 13849) 1)
Performance level:PL d (EN ISO 13849)
PFHd:2.2 * 1E-08
TM (Mission Time):20 a
Enclosure rating:IP 65 (EN 60529)
Protection class:III
Ambient operating temperature from ... to:0 °C ... 55 °C
Vibration resistance (checked to):5 g (IEC 68-2-6)
Oscillation frequency from ... to:10 Hz ... 55 Hz
Shock resistance:10 g, 16 ms (IEC 68-2-29)
Weight:3.88 kg
Supply voltage typical, from, to:24 V DC, 19.2 V DC, 28.8 V DC
Maximum power consumption:6.2 W
Wave length:950 nm
Connection type:plug M12 x 8
Connection type extension connection:plug M12 x 8
Maximum connection cable cross-section:0.25 mm2
1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
Technical Data-Receiver
Protective field height:1,800 mm
Resolution:40 mm
Housing cross-section:48 mm x 40 mm
Type:Type 2 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (IEC 62061)
Category:category 2 (EN ISO 13849)
Test rate (internal test):13 /s (EN ISO 13849)
Maximum demand rate:8 /min (EN ISO 13849) 1)
Performance level:PL d (EN ISO 13849)
PFHd:2.2 * 1E-08
TM (Mission Time):20 a
Enclosure rating:IP 65 (EN 60529)
Protection class:III
Ambient operating temperature from ... to:0 °C ... 55 °C
Vibration resistance (checked to):5 g (IEC 68-2-6)
Oscillation frequency from ... to:10 Hz ... 55 Hz
Shock resistance:10 g, 16 ms (IEC 68-2-29)
Weight:3.88 kg
Response time:18 ms
Supply voltage typical, from, to:24 V DC, 19.2 V DC, 28.8 V DC
Maximum power consumption:8 W
Maximum switching voltage:min. VS - 2.25 V DC
Maximum switching current:500 mA
Wave length:950 nm
Connection type:plug M12 x 8
Connection type extension connection:plug M12 x 8
Maximum connection cable cross-section:0.25 mm2
1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
Products specifications
Manufacturer category Sick C2000
Manufacturer Sick