Functions | Restart interlock: | |
Restart interlock (delivery status): | Deactivated |
External device monitoring (EDM): | |
External device monitoring (delivery status): | Deactivated |
Beam coding: | |
Bypass (with UE402): | - |
Operating mode switching (with UE402): | - |
Type of blanking: | No |
Reduced resolution: | - |
SDL interface: | - |
Muting with: | Flexi Classic, Flexi Soft |
Configuration method: | Hard wired |
Extension connection: | - |
PSDI mode with: | Flexi Soft |
Safe SICK device communication via EFI/SDL: | - |
|
Technical data |
Scanning range from ... to: | 0 m ... 4 m |
Scanning range typ.: | 0 m ... 5 m |
Housing length: | 1,200 mm |
Weight: | 420 g |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Response time: | 13 ms 1) |
Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC |
Maximum switching current: | 300 mA |
Wave length: | 850 nm |
Maximum connection cable cross-section: | 0.34 mm² |
Mounting system type: | C-fix or L-fix bracket |
Extension connection usage: | Stand alone |
Resolution: | 24 mm |
Protective field height: | 1,200 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | Category 4 (EN ISO 13849) |
Performance level: | PL e EN ISO 13849 |
PFHd: | Standalone system: 4.3 * 1E-09 (EN ISO 13849) |
TM (mission time): | 20 a |
Protection class: | III (EN 61140) |
Cable length:: | 700 mm |
Enclosure rating: | IP 65 (EN 60529) |
Ambient operating temperature: | -20 °C ... 55 °C |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Housing cross-section: | 15 mm x 32 mm |
|