Version: |
Long Range |
Connection type: |
Ethernet |
Reading field: |
Front |
Scanner design: |
Line scanner |
Focus: |
Fixed focus |
Light source: |
Visible red light (655 nm) |
MTBF: |
40,000 h |
Laser class: |
2 (EN 60825-1 (A2:2001-03)) |
Field of view: |
≤ 50 ° |
Code resolution: |
0.35 mm ... 1 mm |
Reading distance (at code resolution): |
60 mm ... 730 mm (1 mm) |
Scanning frequency: |
400 Hz ... 1,200 Hz |
Performance |
Bar code types: |
Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, GS1 DataBar, GS1-128 / EAN 128, MSI/Plessey, Pharmacode, Telepen, UPC / GTIN / EAN |
Print ratio: |
2:1 ... 3:1 |
No. of codes per scan: |
1 ... 20 (Standard decoder), 1 ... 6 (SMART620) |
No. of codes per reading interval: |
1 ... 50 (auto-discriminating) |
No. of characters per reading interval: |
1,500, 500 (for multiplexer function in CAN operation) |
No. of multiple readings: |
1 ... 99 |
Interfaces |
Serial (RS-232, RS-422/485): |
|
Remark (Serial (RS-232, RS-422/485)): |
AUX (only RS-232) |
Function (Serial (RS-232, RS-422/485)): |
Host, AUX |
Data transmission rate (Serial (RS-232, RS-422/485)): |
2,400 Baud ... 115 kBaud, AUX: 57.6 kBaud |
Ethernet: |
|
Function (Ethernet): |
Host, AUX |
Protocol (Ethernet): |
TCP/IP, EtherNet/IP, PROFINET, PROFINET Dual Port (optional via external connection module CDF600-2), EtherCAT (optional via external connection module CDF600) |
Data transmission rate (Ethernet): |
10/100 Mbit |
CAN bus: |
|
Function (CAN bus): |
SICK CAN sensor network (Master/Slave, Multiplexer/Server) |
Protocol (CAN bus): |
CANopen, CSN (SICK CAN Sensor Network) |
Data transmission rate (CAN bus): |
20 kbit/s ... 1 Mbit/s |
PROFIBUS DP: |
|
Remark (PROFIBUS DP): |
Optional via external connection module (CDF600-2) |
DeviceNet: |
|
Remark (DeviceNet): |
Optional via external connection module (CDM + CMF) |
Switching inputs: |
3 (“Sensor 1”, 2 inputs via optional CMC600 in CDB620/CDM420) |
Switching outputs: |
2 (via CMC600 in CDB620/CDM420) |
Reading pulse: |
Auto pulse, CAN, Non-powered, Switching inputs, Serial interface |
Optical indicators: |
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX) |
Acoustic indicators: |
Beeper/buzzer (can be switched off, can be allocated as a result indication function) |
Configuration software: |
SOPAS |
Mechanics/electronics |
Electrical connection: |
2 M12 cylindrical connectors (12-pin male connector, 4-pin female connector) on swivel connector |
Operating voltage: |
10 V DC ... 30 V DC |
Power consumption: |
4.5 W |
Housing: |
Die-cast aluminum |
Housing color: |
Light blue (RAL 5012) |
Enclosure rating: |
IP 65 (DIN 40 050) |
Protection class: |
III (VDE 0106/IEC 1010-1) |
Weight: |
205 g, without connecting cable |
Dimensions: |
61 mm x 66 mm x 38 mm 1) |
Ambient data |
Electromagnetic compatibility (EMC): |
EN 61000-6-3 (2001-10) / EN 61000-6-2:2005 |
Vibration resistance: |
EN 60068-2-6 (1995) |
Shock resistance: |
EN 60068-2-27 (1993) |
Ambient operating temperature: |
0 °C ... +40 °C |
Storage temperature: |
-20 °C ... +70 °C |
Permissible relative humidity: |
90 %, non-condensing |
Ambient light safety: |
2,000 lx, on bar code |
Bar code print contrast (PCS): |
≥ 60 % |