Error limits: |
± 0.3 ° |
Measuring step: |
90 ° / electronically/number of lines |
Initialization time: |
40 ms |
Pulses per revolution: |
1,000 |
Mechanical data |
Mechanical interface: |
Through hollow shaft |
Shaft diameter: |
14 mm |
Mass: |
0.2 kg |
Start up torque: |
0.8 Ncm (20 °C) |
Operating torque: |
0.6 Ncm (20 °C) |
Permissible movement axial static/dynamic: |
± 0.5 mm, ± 0.2 mm |
Permissible movement radial static/dynamic: |
± 0.3 mm, ± 0.1 mm |
Maximum operating speed: |
9,000 /min |
Moment of inertia of the rotor: |
40 gcm² |
Bearing lifetime: |
3.6 x 10^10 revolutions |
Max. angular acceleration: |
500,000 rad/s² |
Shaft material: |
Metal |
Electrical data |
Electrical interface: |
4.5 V ... 5.5 V, TTL/RS422, Cable, 8-pin, universal, 5 m |
Connection type: |
Cable, 8-pin, universal, 5 m 1) |
Maximum output frequency: |
300 kHz |
Reference signal, number: |
1 |
Reference signal, position: |
90 °, electronically, gated with A and B |
Operating voltage range: |
4.5 V ... 5.5 V |
Load current max.: |
30 mA |
MTTFd: mean time to dangerous failure: |
300 a (EN ISO 13849-1) 2) |
Ambient data |
EMC: |
(according to EN 61000-6-2 and EN 61000-6-3) |
Working temperature range: |
0 °C ... 85 °C |
Storage temperature range: |
-40 °C ... 100 °C, without package |
Resistance to shocks: |
50 g (according to EN 60068-2-27) |
Resistance to vibration: |
20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
Enclosure rating: |
IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529) |
Permissible relative humidity: |
90 % (condensation of the optical scanning not permitted) |