Measuring range 1): |
0.15 m ... 150 m, on reflective tape "Diamond Grade" |
Resolution: |
0.05 mm ... 5 mm |
Repeatability 2) 3): |
1 mm |
Accuracy: |
± 3 mm |
Light source 4): |
Laser, red |
Typ. light spot size (distance): |
130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) |
Output rate: |
2 ms |
Max. movement speed: |
10 m/s |
Laser class: |
2 (EN 60825-1 / CDRH) |
Interfaces |
Data interface: |
DeviceNet |
Switching output 1): |
Push-pull: PNP/NPN (100 mA) |
Multifunctional input (MF) 2) 3): |
1 x MF |
Mechanics/electronics |
Supply voltage Vs: |
DC 18 V ... 30 V, limit values |
Ripple 1): |
< 5 Vpp |
Initialization time 2): |
1.5 s |
Indication: |
Display |
Weight: |
Ca. 1,650 g |
Output current IA 3): |
≤ 100 mA |
Power consumption: |
At 24 V DC < 250 mA |
Connection type: |
Male connector, 1 x M12, 4-pin, A-coded, 1 x M16, 8-pin |
Ambient data |
Enclosure rating: |
IP 65 |
Protection class 1): |
II |
Effect of air pressure: |
0.3 ppm/hPa |
Effect of air temperature: |
1 ppm/K |
Temperature drift: |
Typ. 0.1 mm/K |
Ambient temperature: |
Operation: -10 ... 55 °C Operation with cooling case: -10 ... 75 °C Storage: -25 ... 75 °C |
Mechanical load: |
Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 |
Electromagnetic compatibility (EMC): |
EN 61000-6-2, EN 55011 |