Select Store:
Select Currency:

Sick DMT10-2-1113 (1027605)

Product Summary

Distance measuring device DMT10-2-1113 for high temperatures
Manufacturer: Sick
Manufacturer part number: 1027605
SKU: 149530
Weight(kg): 1.7750

Click here to check availability

Pricing - Condition Manufacturer New

£8,918.97 excl VAT
£8,588.97 excl VAT

Downloads

  • Measurement range from 0.5 m up to 155 m on natural targets
  • Excellent accuracy thanks to time-of-flight measurement
  • Easy alignment thanks to pilot laser
  • Freely programmable parameters
  • RS-422, RS-232, PROFIBUS, analog and two switching outputs
  • Near field blanking parameter for operation through a protection window
  • Models with filter for measurement of glowing, hot metal (up to 1,400 °C)
  • Your benefits

  • Extremely wide measurement range of up to 155 m on natural targets offers high flexibility in applications where range is key
  • Supplementary visible alignment laser allows fast and easy alignment - even over long distances, offering fast and cost-effective installation
  • Tough metal housing design for trouble-free operation in the roughest environmental conditions
  • Non-visible, Class 1 IR laser for safe measurement and detection
  • User-friendly software with an easy-to-follow interface ensures fast and cost-optimized setup
  • Serial and analog interfaces as well as two digital switching outputs allow flexible use for varied applications
  • Integrated filter option allows for direct measurement of 1,400 °C glowing, hot targets

Performance
Measuring range 1):0.5 m ... 20 m
Resolution:≤ 1 mm
Repeatability 2) 3) 4) 5):10 mm, 7 mm
Accuracy 6) 7):± 10 mm
Light source:Laser, infrared
Typ. light spot size (distance):20 mm (+ 5 x distance in m)
Average depth:1/16/64/256/1,024
Output rate 8):1 ms ... 4,000 ms
Aperture delay time:1 s 9)
Note:Mechanical aperture
Response time 10):1 ms ... 4,000 ms
Cycle time:1,024 per sec.
Special characteristic:Mechanical aperture
Laser class:1 (EN 60825-1:Nov.2001, IEC 60825-1:ÄM2:2001)
1) Max. object temperature 1,400 °C  2) Dependant on distance and remission, 7 mm, at 6 % ... 90 % remission from 0.5 m ... 65 m, at 6 % ... 18 % remission from 0.5 m ... 40 m, at 6 % remission from 0.5 m ... 15 m  3) 5) Environmental conditions constant, min. warm-up time 30 min, average depth 1,024, statistical error 1 s  4) Dependant on distance and remission, 10 mm, at 6 % ... 90 % remission from 60 m ... 155 m, at 6 % ... 18 % remission from 40 m ... 65 m, at 6 % remission from 15 m ... 40 m  6) 23 °C air temperature, 977 hPa, min. warm-up time 30 min.  7) When operating in ambient temperatures between +40 °C ... +55 °C the accuracy can decrease by factor 2.5  8) 9) Dependant on average setting, average depth, timeout, baud rate, data outpu and output format  10) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture  
Interfaces
Data interface 1):RS-422 RS-232
Switching output 2):Q1, Q2
Interface for parametrization:RS-232
Analog output:4 mA ... 20 mA, scalable
1) Switchable  2) Output Q short-circuit protected  
Mechanics/electronics
Supply voltage Vs:DC 18 V ... 30 V, limit values
Ripple 1):< 5 Vpp
Initialization time:6 s
Weight:Ca. 1,200 g
Output current IA:100 mA
Power consumption 2):≤ 6 W
Connection type:1 x cable gland, 1 x Sub-D, 9-pin
1) May not fall short of or exceed VS tolerances  2) Without load  
Ambient data
Enclosure rating:IP 65
Protection class 1):III
Temperature drift 2) 3):Typ. 0.3 mm/K
Typ. 0.6 mm/K
Ambient temperature:Operation: -10 ... 55 °C
Operation with cooling case: -10 ... 75 °C
Storage: -25 ... 70 °C
Mechanical load:Shock: IEC 60068-2-27, -2-29
Sine: IEC 60068-2-6
Electromagnetic compatibility (EMC):EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2
1) Reference voltage DC 50 V PELV-voltage (EN 50178)  2) -10° C ... 0° C, +40 °C … +55 °C  3) 0 °C ... +40 °C  
Products specifications
Manufacturer category Sick DMT
Manufacturer Sick