Measurement range: |
200 mm ... 20,000 mm, 90 % remision 200 mm ... 5,000 mm, 6 % remission 200 mm ... 8,500 mm, 18 % remission |
Resolution: |
1 mm |
Repeatability 1) 2) 3): |
3 mm / 2 mm / 1 mm |
Accuracy 4): |
± 7 mm |
Response time 5) 6): |
15 ms / 30 ms / 80 ms |
Output rate 7): |
≥ 2 ms |
Light source: |
Laser, red |
Typ. light spot size (distance): |
15 mm x 15 mm (10 m) |
Additional function: |
Switch-off display Teach-in of analog output Teach-in of switching output Set moving average fast/medium/slow Set hysteresis Scaling of analog outputs Set levels of switching outputs Switching mode: distance to object (DtO) Lock user interface Reset to factory default Multifunctional input: laser off / external teach / inactive Invertible analog output Switching output invertible |
Laser class: |
2 (EN 60825-1) 8) |
Laser service life (MTTF at 25 °C): |
100,000 h |
Interfaces |
Analog output: |
1 x 4 mA ... 20 mA (≤ 300 Ω) |
Resolution analog output: |
16 bit |
Output type: |
1 x PNP (100 mA) 1) 2) |
Hysteresis: |
10 mm ... 1,000 mm |
Multifunctional input (MF) 3) 4): |
1 x |
Mechanics/electronics |
Supply voltage Vs 1): |
DC 10 V ... 30 V |
Ripple 2): |
≤ 5 Vpp |
Power consumption 3): |
≤ 2.1 W |
Initialization time: |
≤ 250 ms |
Warm-up time: |
≤ 15 min |
Housing material: |
Die-cast zinc housing (ZNAL4CU1) acrylic glass (PMMA) |
Connection type: |
Male connector, M12, 5-pin |
Indication: |
2 x LED, LC display |
Weight: |
200 g |
Ambient data |
Enclosure rating: |
IP 65 |
Protection class: |
III |
Ambient temperature: |
Operation: -30 ... 65 °C, Storage: -40 ... 75 °C |
Max. rel. humidity (not condensing): |
≤ 95 % |
Vibration resistance: |
EN 60068-2-6 / EN 60068-2-64 |
Shock resistance: |
EN 60068-2-27 |
Typ. ambient light safety: |
40 klx |