FX3-XTDI80002 Flexi Soft Extension Module 8 Safety Inputs
Manufacturer: Sick
Manufacturer part number: 1044124
SKU: 181407
Weight(kg): 0.2100

Click here to check availability

Pricing - Condition Manufacturer New

£173.90 excl VAT
£165.20 excl VAT
  • XTDI input extension with eight safety inputs and eight test pulse outputs
  • XTIO input/output extension with eight safety inputs and four safety outputs (according to SIL3)
  • XTDS input/output extension with eight safety inputs, four standard outputs, two switchable outputs or test pulse outputs
  • STIO input/output extension with six inputs, six outputs, two switchable inputs or outputs
  • Your benefits

  • Connection of all commercially available sensors provides greater flexibility
  • Low number of inputs and outputs per module eliminates extra inputs/outputs and reduces costs
  • The fast-shut-off function reduces the response time, which allows the safety equipment to be installed closer to the hazardous point and reduces the overall footprint of the equipment
  • Low-cost diagnostic function using standard outputs without an additional gateway
  • Optimal system design with Flexi Soft expansion modules (up to 12 modules can be connected)
  • Direct integration of standard automation in the safety control system

Safety-related parameters
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category:Category 4 (EN ISO 13849-1)
Performance level:PL e (EN ISO 13849-1)
PFHd:0.4 * 1E-09 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Functions
Flexi Loop-compatible:
Fast shut-off:-
Mechanical data
Dimensions (W x H x D):22.5 mm x 96.5 mm x 120.6 mm
Weight:139 g (± 5 %)
Electrical data
Protection class:III (EN 61140)
Voltage supply internal logic:Via FLEXBUS+
Voltage supply test signal outputs:Via FLEXBUS+
Internal power consumption:≤ 2 W 1)
1) Via FLEXBUS+, without current on test signal outputs  
Interfaces
Connection type:Spring terminals
Number of safety inputs:8 (I1 - I8)
Number of non-safe inputs:0
Number of safe outputs:0
Number of test signal outputs:8 (X1 - X8)
Number of non-safe outputs:0
Ambient data
Enclosure rating terminals:IP 20 (EN 60529)
Protection class housing:IP 40 (EN 60529)
Ambient operating temperature:-25 °C ... 55 °C
Storage temperature:-25 °C ... 70 °C
Air humidity:10 % ... 95 %, non-condensing
Climate conditions according to:EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity)
Electromagnetic compatibility (EMC):Class A (EN 61000-6-2, EN 55011)
Vibration resistance:1 g, 5 Hz ... 150 Hz (EN 60068-2-6)
3 g RMS, 10 Hz ... 500 Hz (EN 60068-2-64)
Shock resistance (continuous shock):10 g, 16 ms (EN 60068-2-27)
Shock resistance (single shock):30 g, 11 ms (EN 60068-2-27)
Products specifications
Manufacturer category Sick UE100