Select Store:
Select Currency:

Sick FX3-XTIO84002 (1044125)

Product Summary

FX3-XTIO84002 Flexi Soft Extension Module 8 Safety Inputs / 4 Safety Outputs
Manufacturer: Sick
Manufacturer part number: 1044125
SKU: 181408
Weight(kg): 0.2360

Click here to check availability

Pricing - Condition Manufacturer New

£350.02 excl VAT
£339.51 excl VAT
    • XTDI input extension with eight safety inputs and eight test pulse outputs
    • XTIO input/output extension with eight safety inputs and four safety outputs (according to SIL3)
    • XTDS input/output extension with eight safety inputs, four standard outputs, two switchable outputs or test pulse outputs
    • STIO input/output extension with six inputs, six outputs, two switchable inputs or outputs

Your benefits

  • Connection of all commercially available sensors provides greater flexibility
  • Low number of inputs and outputs per module eliminates extra inputs/outputs and reduces costs
  • The fast-shut-off function reduces the response time, which allows the safety equipment to be installed closer to the hazardous point and reduces the overall footprint of the equipment
  • Low-cost diagnostic function using standard outputs without an additional gateway
  • Optimal system design with Flexi Soft expansion modules (up to 12 modules can be connected)
  • Direct integration of standard automation in the safety control system

 

Safety-related parameters

Safety integrity level: SIL3 (IEC 61508)
SILCL3 (EN 62061)
Category: Category 4 (EN ISO 13849-1)
Performance level: PL e (EN ISO 13849-1)
PFHd: 4.8 * 1E-09 (EN ISO 13849)
0.9 * 1E-09 (EN ISO 13849) 1)
TM (mission time): 20 a (EN ISO 13849)
1) 0.9 * 1E-09 for single channel outputs and 4.8 * 1E-09 for dual channel outputs  
Functions
Flexi Loop-compatible:
Fast shut-off:
Fast shut-off time: 8 ms
 
Mechanical data
Dimensions (W x H x D): 22.5 mm x 96.5 mm x 120.6 mm
Weight: 164 g (± 5 %)
 
Electrical data
Protection class: III (EN 61140)
Voltage supply internal logic: Via FLEXBUS+
Voltage supply test signal outputs: Via FLEXBUS+
Voltage supply safe outputs: Via A1, A2
Internal power consumption: ≤ 2.2 W 1)
1) Via FLEXBUS+, without current on test signal outputs  
Interfaces
Connection type: Spring terminals
Number of safety inputs: 8 (I1 - I8)
Number of non-safe inputs: 0
Number of safe outputs: 4 (Q1 - Q4)
Number of test signal outputs: 2 (X1, X2)
Number of non-safe outputs: 0
 
Ambient data
Enclosure rating terminals: IP 20 (EN 60529)
Protection class housing: IP 40 (EN 60529)
Ambient operating temperature: -25 °C ... 55 °C
Storage temperature: -25 °C ... 70 °C
Air humidity: 10 % ... 95 %, non-condensing
Climate conditions according to: EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity)
Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011)
Vibration resistance: 1 g, 5 Hz ... 150 Hz (EN 60068-2-6)
3 g RMS, 10 Hz ... 500 Hz (EN 60068-2-64)
Shock resistance (continuous shock): 10 g, 16 ms (EN 60068-2-27)
Shock resistance (single shock): 30 g, 11 ms (EN 60068-2-27)
 
Products specifications
Manufacturer category Sick UE100
Manufacturer Sick