Features | Task: | Positioning Inspection Reading Measuring |
Technology: | 2D, Image analysis, Snapshot |
Example field of view (H x W): | See Field of view diagram |
Offline support: | Emulator |
Spectral range: | Ca. 400 nm ... 750 nm |
|
Performance |
Image sensor: | 1/3" CCD, electronic shutter |
Processor: | 800 MHz |
Memory: | 128 MB RAM, 16 MB flash |
Maximum performance: | 24 Hz |
Resolution: | 1,024 px x 768 px |
|
Interfaces |
Operator interfaces: | Application specific operator interfaces can be created using ActiveX (COM) or as web page. Included OPC server enables data exchange with e.g. SCADA systems. |
Configuration software: | IVC Studio |
Data store and retrieve: | Images and data can be stored to and retrieved from flash and external FTP servers |
Communication interfaces: | RS-485 Fast Ethernet (10/100 Mbit/s): TCP/IP, UDP/IP, EtherNet/IP OPC server included |
Digital inputs: | 4 program controlled inputs (1 trigger input), HIGH = 10 V ... 28.8 V |
Digital outputs: | 3 B-type program controlled outputs Total output load < 100 mA Trigger output |
|
Mechanics/electronics |
Connectors: | M12, 4-pin female connector, D-coded (Ethernet) M12, 8-pin female connector (RS-485) M12, 8-pin male connector (power I/O) |
Connector material: | Nickel plated brass |
Supply voltage: | 24 V DC± 20 % |
Power consumption: | < 400 mA Without output load |
Ripple: | < 5 Vpp |
Enclosure rating: | IP 54 IP 65 with lens protection hood |
Protection class: | II, III |
Housing material: | Anodized aluminum |
Weight: | 505 g |
Dimensions (L x W x H): | 161 mm x 60 mm x 55 mm |
Optics: | C or CS-mount |
|
Ambient data |
Shock load: | 15 g, 3 x 6 directions |
Vibration load: | 5 g, 58 Hz ... 150 Hz |
Ambient operating temperature: | 0 °C ... 50 °C 1) |
Ambient storage temperature: | -20 °C ... 70 °C 2) |
|