Select Store:
Select Currency:

Sick M20E-071A3A221 (1018225)

Product Summary

Multi-Beam Safety Light Barrier, testable, receiver M20E-071A3A221, RES/EDM, cascadable, 7 beams, 170 mm resolution, range: 0...25 m, Hirschmann plug
Manufacturer: Sick
Manufacturer part number: 1018225
SKU: 148082
Weight(kg): 3.0500

Click here to check availability

Pricing - Condition Manufacturer New

£775.12 excl VAT
£736.36 excl VAT
Applications
Access protection (vertical):
Hazardous area protection (horizontal):
Functions
Restart interlock:
Functions-Sender
System construction:Sender/receiver system
Beam coding:
Self-testing:
Configurable scanning range:
Configuration method:hard wired
Safe device communication via EFI/SDL:-
Functions-Receiver
System construction:Sender/receiver system
External device monitoring:
Beam coding:
Self-testing:
Muting with:Flexi Classic, Flexi Soft
Configuration method:hard wired
Safe device communication via EFI/SDL:-
Technical Data-Sender
Number of beams:7
Resolution:170 mm
Scanning range from ... to:0 m ... 25 m
Type:Type 2 (according to IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:category 2 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:2.2 * 1E-08
TM (Mission Time):20 a
Housing cross-section:48 mm x 40 mm
Supply voltage typical, from, to:DC, 24 V, 19.2 V, 28.8 V
Maximum power consumption:3.7 W
Protection class:III
Enclosure rating:IP 65 (according to EN 60529)
Ambient operating temperature from ... to:0 °C ... 55 °C
Vibration resistance (checked to):5 g (IEC 68-2-6)
Oscillation frequency from ... to:10 Hz ... 55 Hz
Shock resistance:10 g, 16 ms (according to IEC 68-2-29)
System connection:Hirschmann plug
Maximum connection cable cross-section:1 mm2
Display elements:7-segment
Test rate (internal test):13 /s (EN ISO 13849)
Maximum demand rate:8 /min (EN ISO 13849) 1)
1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
Technical Data-Receiver
Number of beams:7
Scanning range from ... to:0 m ... 25 m
Resolution:170 mm
Housing cross-section:48 mm x 40 mm
Type:Type 2 (according to IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:category 2 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:2.2 * 1E-08
TM (Mission Time):20 a
Maximum response time:8 ms
Supply voltage typical, from, to:DC, 24 V, 19.2 V, 28.8 V
Maximum switching voltage:Uv-2.25 V
Maximum switching current:500 mA
Maximum power consumption:5 W
Protection class:III
Enclosure rating:IP 65 (according to EN 60529)
Ambient operating temperature from ... to:0 °C ... 55 °C
System connection:Hirschmann plug
Maximum connection cable cross-section:1 mm2
Vibration resistance (checked to):5 g (IEC 68-2-6)
Oscillation frequency from ... to:10 Hz ... 55 Hz
Shock resistance:10 g, 16 ms (according to IEC 68-2-29)
Display elements:7-segment
Test rate (internal test):13 /s (EN ISO 13849)
Maximum demand rate:8 /min (EN ISO 13849) 1)
1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
Products specifications
Manufacturer category Sick M2000H
Manufacturer Sick