Applications | Access protection (vertical): | |
Hazardous area protection (horizontal): | |
|
Functions |
Restart interlock: | |
|
Functions-Sender |
System construction: | Sender/receiver system |
Beam coding: | |
Self-testing: | |
Configurable scanning range: | |
Configuration method: | hard wired |
Safe device communication via EFI/SDL: | - |
|
Functions-Receiver |
System construction: | Sender/receiver system |
External device monitoring: | |
Beam coding: | |
Self-testing: | |
Muting with: | Flexi Classic, Flexi Soft |
Configuration method: | hard wired |
Safe device communication via EFI/SDL: | - |
|
Technical Data-Sender |
Number of beams: | 7 |
Resolution: | 170 mm |
Scanning range from ... to: | 0 m ... 25 m |
Type: | Type 2 (according to IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: | category 2 (EN ISO 13849) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 2.2 * 1E-08 |
TM (Mission Time): | 20 a |
Housing cross-section: | 48 mm x 40 mm |
Supply voltage typical, from, to: | DC, 24 V, 19.2 V, 28.8 V |
Maximum power consumption: | 3.7 W |
Protection class: | III |
Enclosure rating: | IP 65 (according to EN 60529) |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (according to IEC 68-2-29) |
System connection: | Hirschmann plug |
Maximum connection cable cross-section: | 1 mm2 |
Display elements: | 7-segment |
Test rate (internal test): | 13 /s (EN ISO 13849) |
Maximum demand rate: | 8 /min (EN ISO 13849) 1) |
|
Technical Data-Receiver |
Number of beams: | 7 |
Scanning range from ... to: | 0 m ... 25 m |
Resolution: | 170 mm |
Housing cross-section: | 48 mm x 40 mm |
Type: | Type 2 (according to IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: | category 2 (EN ISO 13849) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 2.2 * 1E-08 |
TM (Mission Time): | 20 a |
Maximum response time: | 8 ms |
Supply voltage typical, from, to: | DC, 24 V, 19.2 V, 28.8 V |
Maximum switching voltage: | Uv-2.25 V |
Maximum switching current: | 500 mA |
Maximum power consumption: | 5 W |
Protection class: | III |
Enclosure rating: | IP 65 (according to EN 60529) |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
System connection: | Hirschmann plug |
Maximum connection cable cross-section: | 1 mm2 |
Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (according to IEC 68-2-29) |
Display elements: | 7-segment |
Test rate (internal test): | 13 /s (EN ISO 13849) |
Maximum demand rate: | 8 /min (EN ISO 13849) 1) |
|