Select Store:
Select Currency:

Sick M20S-03140A122 (1018188)

Product Summary

Multi-Beam Safety Light Barrier, testable, sender M20S-03140A122, 3 beams, 400 mm beam gap, range: 0...25 m, M12 plug
Manufacturer: Sick
Manufacturer part number: 1018188
SKU: 148050
Weight(kg): 1.9400

Click here to check availability

Pricing - Condition Manufacturer New

£438.00 excl VAT
£422.67 excl VAT
    • Wide scanning range up to 70 m
    • External device monitoring (EDM), restart interlock (RES), and internal self-testing configurable without PC
    • Robust housing with an industrial design
    • Standardized M12 connectivity is available
    • 7-segment display
    • Beam coding for correct system allocation

Your benefits

  • The wide scanning range spectrum allows the device to be standardized for the relevant application
  • High level of resistance and robust design for high machine availability, even under special ambient conditions
  • Customized protection field adaption with deflection mirror for reduced installation costs
  • Customer-friendly interfaces and status display facilitate commissioning and maintenance
  • Reduced downtimes through diagnostics displays directly on the device
  • Integrated additional functions: Reset and EDM for short cable paths and connection to cost-optimized, positively guided relays
  • Fast start-up times by easy alignment using the optional laser alignment aid (separate accessories)

 

Applications

Access protection (vertical):
Hazardous area protection (horizontal): -
 
Functions
Restart interlock:
 
Functions-Sender
System construction: Sender/receiver system
Beam coding:
Self-testing:
Configurable scanning range:
Configuration method: hard wired
Safe device communication via EFI/SDL: -
 
Functions-Receiver
System construction: Sender/receiver system
External device monitoring:
Beam coding:
Self-testing:
Muting with: Flexi Classic, Flexi Soft
Configuration method: hard wired
Safe device communication via EFI/SDL: -
 
Technical Data-Sender
Number of beams: 3
Resolution: 400 mm
Scanning range from ... to: 0 m ... 25 m
Type: Type 2 (according to IEC 61496)
Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061)
Category: category 2 (EN ISO 13849)
Performance level: PL d (EN ISO 13849)
PFHd: 2.2 * 1E-08
TM (Mission Time): 20 a
Housing cross-section: 48 mm x 40 mm
Supply voltage typical, from, to: DC, 24 V, 19.2 V, 28.8 V
Maximum power consumption: 3.7 W
Protection class: III
Enclosure rating: IP 65 (according to EN 60529)
Ambient operating temperature from ... to: 0 °C ... 55 °C
Vibration resistance (checked to): 5 g (IEC 68-2-6)
Oscillation frequency from ... to: 10 Hz ... 55 Hz
Shock resistance: 10 g, 16 ms (according to IEC 68-2-29)
System connection: plug
Maximum connection cable cross-section: 0.25 mm2
Display elements: 7-segment
Test rate (internal test): 13 /s (EN ISO 13849)
Maximum demand rate: 8 /min (EN ISO 13849) 1)
1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
Technical Data-Receiver
Number of beams: 3
Scanning range from ... to: 0 m ... 25 m
Resolution: 400 mm
Housing cross-section: 48 mm x 40 mm
Type: Type 2 (according to IEC 61496)
Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061)
Category: category 2 (EN ISO 13849)
Performance level: PL d (EN ISO 13849)
PFHd: 2.2 * 1E-08
TM (Mission Time): 20 a
Maximum response time: 8 ms
Supply voltage typical, from, to: DC, 24 V, 19.2 V, 28.8 V
Maximum switching voltage: Uv-2.25 V
Maximum switching current: 500 mA
Maximum power consumption: 5 W
Protection class: III
Enclosure rating: IP 65 (according to EN 60529)
Ambient operating temperature from ... to: 0 °C ... 55 °C
System connection: plug
Maximum connection cable cross-section: 0.25 mm2
Vibration resistance (checked to): 5 g (IEC 68-2-6)
Oscillation frequency from ... to: 10 Hz ... 55 Hz
Shock resistance: 10 g, 16 ms (according to IEC 68-2-29)
Display elements: 7-segment
Test rate (internal test): 13 /s (EN ISO 13849)
Maximum demand rate: 8 /min (EN ISO 13849) 1)
1) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
Products specifications
Manufacturer category Sick M2000
Manufacturer Sick