Access protection (vertical): |
|
Access protection with muting: |
- |
Hazardous area protection (horizontal): |
- |
Functions-Sender |
System construction: |
Sender/receiver system |
Beam coding: |
|
Beam coding (delivery status): |
Non-coded |
Sender test: |
|
Sender test (delivery status): |
deactivated |
Integrated laser alignment aid: |
|
SDL interface: |
- |
Configuration method: |
configuration buttons |
Safe device communication via EFI/SDL: |
- |
Muting with: |
Flexi Classic |
Functions-Receiver |
System construction: |
Sender/receiver system |
Restart interlock: |
|
Restart interlock (delivery status): |
Activated |
External device monitoring: |
|
External device monitoring (delivery status): |
Activated |
Beam coding: |
|
Beam coding (delivery status): |
Non-coded |
Muting with: |
Flexi Classic |
Configurable application diagnostic output: |
|
Application diagnostic output (delivery status): |
Contamination (OWS) |
Configurable scanning range: |
|
Scanning range (delivery status): |
20 m |
Integrated laser alignment aid: |
|
End cap with integrated LED: |
- |
Additional reset connection: |
- |
SDL interface: |
- |
Configuration method: |
configuration buttons |
Safe device communication via EFI/SDL: |
- |
Technical Data-Sender |
Number of beams: |
2 |
Resolution: |
500 mm |
Scanning range Low Range: |
0.5 m ... 20 m |
Scanning range High Range: |
15 m ... 70 m |
Scanning range from ... to: |
0.5 m ... 70 m, configurable |
Type: |
Type 4 (IEC 61496) |
Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
6.6 * 1E-09 |
TM (Mission Time): |
20 a |
Housing cross-section: |
52 mm x 55.5 mm |
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
Power consumption: |
0.2 |
Protection class: |
III (EN 50178:1998) |
Enclosure rating: |
IP 65 (EN 60529) |
Ambient operating temperature from ... to: |
-10 °C ... 55 °C |
Vibration resistance (checked to): |
5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
Shock resistance: |
10 g, 16 ms (IEC 60068-2-29) |
System connection: |
plug |
Display elements: |
LED/7-segment |
Technical Data-Receiver |
Number of beams: |
2 |
Scanning range from ... to: |
0.5 m ... 70 m, configurable |
Resolution: |
500 mm |
Scanning range Low Range: |
0.5 m ... 20 m |
Scanning range High Range: |
15 m ... 70 m |
Scanning range from ... to (delivery status): |
0 m ... 20 m |
Housing cross-section: |
52 mm x 55.5 mm |
Type: |
Type 4 (IEC 61496) |
Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
6.6 * 1E-09 |
TM (Mission Time): |
20 a |
Maximum response time: |
10 ms |
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
Power consumption: |
≤ 0.6 A 1) |
Type of output: |
Safety outputs (OSSD) |
Maximum switching voltage: |
UV - 2,25 V |
Maximum switching current: |
500 mA |
Protection class: |
III (EN 50178:1998) |
Enclosure rating: |
IP 65 (EN 60529) |
Ambient operating temperature from ... to: |
-10 °C ... 55 °C |
System connection: |
plug |
Vibration resistance (checked to): |
5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
Shock resistance: |
10 g, 16 ms (IEC 60068-2-29) |
Display elements: |
LED/7-segment |