Applications | Hazardous area protection (horizontal): | |
Access protection (vertical): | |
Access protection with muting: | |
|
Functions-Sender |
System construction: | Sender/receiver system |
Beam coding: | |
Beam coding (delivery status): | Non-coded |
Sender test: | |
Sender test (delivery status): | deactivated |
Integrated laser alignment aid: | - |
SDL interface: | |
Configuration method: | PC with CDS (Configuration and Diagnostic Software) |
Safe device communication via EFI/SDL: | |
|
Functions-Receiver |
System construction: | Sender/receiver system |
Restart interlock: | |
Restart interlock (delivery status): | Activated |
External device monitoring: | |
External device monitoring (delivery status): | Activated |
Beam coding: | |
Beam coding (delivery status): | Non-coded |
Muting with: | UE403 |
Belt stop (with UE403): | |
Concurrence monitoring (with UE403): | |
Monitoring total muting time (with UE403): | |
End of muting by ESPE (with UE403): | |
Sensor gap monitoring (with UE403): | |
Sensor test (with UE403): | |
Partial blanking (with UE403): | |
Configurable application diagnostic output: | |
Application diagnostic output (delivery status): | Contamination (OWS) |
Configurable scanning range: | |
Integrated laser alignment aid: | - |
End cap with integrated LED: | - |
Additional reset connection: | - |
SDL interface: | |
Configuration method: | PC with CDS (Configuration and Diagnostic Software) |
Scanning range (delivery status): | 2.5 m |
Extension connection: | |
Safe device communication via EFI/SDL: | |
Exit monitoring (with UE403): | |
Reading mode: | |
CDS data recorder: | |
Event history: | |
|
Technical Data-Sender |
Protective field height: | 1,050 mm |
Resolution: | 14 mm |
Housing cross-section: | 52 mm x 55.5 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
TM (Mission Time): | 20 a |
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | III (EN 50178:1998) |
Ambient operating temperature from ... to: | -10 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Supply voltage typical, from, to: | 24 V, 19.2 V, 28.8 V |
Power consumption: | ≤ 0.2 A |
Display elements: | LED/7-segment |
System connection: | Hirschmann plug |
|
Technical Data-Receiver |
Protective field height: | 1,050 mm |
Resolution: | 14 mm |
Scanning range from ... to: | 0 m ... 8 m |
Scanning range from ... to (delivery status): | 0 m ... 2.5 m |
Housing cross-section: | 52 mm x 55.5 mm |
Type: | Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
TM (Mission Time): | 20 a |
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | III (EN 50178:1998) |
Ambient operating temperature from ... to: | -10 °C ... 55 °C |
Vibration resistance (checked to): | 5 g (IEC 60068-2-6) |
Oscillation frequency from ... to: | 10 Hz ... 55 Hz |
Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) |
Response time without beam coding: | ≤ 12 ms |
Response time with beam coding: | ≤ 20 ms |
Supply voltage typical, from, to: | 24 V, 19.2 V, 28.8 V |
Power consumption: | ≤ 0.6 A 1) |
Type of output: | Safety outputs (OSSD) |
Switching voltage typ, from, to: | UV - 2,25 V, 24 V DC, UV |
Maximum switching current: | 500 mA |
Display elements: | LED/7-segment |
System connection: | Hirschmann plug M26 x 11 + FE |
Connection type configuration connection: | plug M12 x 5 |
|