Features | Technology: | Sender/receiver |
Task: | Measurement light grid |
Minimum detectable object (MDO) 1): | Parallel beam: ≥15 mm |
Beam separation: | 10 mm |
Number of beams: | 15 |
Detection height: | 140 mm |
Configuration: | Parameterization interface (measuring) |
|
Performance |
Maximum range 1): | 7 m |
Minimum range: | Parallel beam: ≥0 mm |
Response time 2): | Parallel beam: ≥3.25 ms |
Working range 3): | 5 m |
|
Interfaces |
Switching output: | 3 x PNP |
Inputs: | 1 x PNP |
Connection type: | Connector M12, 8-pin |
IO-Link: | 0 |
|
Mechanics/electronics |
Wave length: | IR 880 nm |
Supply voltage Vs 1): | DC 18 V ... 30 V |
Power consumption sender 2): | 170 mA |
Power consumption receiver 3): | 145 mA |
Ripple: | < 5 Vpp |
Output current Imax.: | 100 mA |
Output load capacitive: | 100 nF |
Output load inductive: | 1 H |
Initialization time: | 1 s |
Dimensions (W x H x D): | 34 mm x 214 mm x 29 mm |
Housing material: | Aluminum |
Indication: | 7-segment display, LED |
Synchronization: | Cable |
Enclosure rating: | IP 65 |
Circuit protection: | Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected |
Weight: | 0.822 kg |
Power consumption: | 170 mA 4) |
Front screen: | PMMA |
|
Ambient data |
Protection class: | III |
EMC: | EN 60947-5-2 |
Ambient temperature: | Operation: -25 ... +55 °C, Storage: -40 ... +70 °C |
Ambient light safety 1) 2): | Direct: ≥12,500 lx, Indirect: ≥50,000 lx |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) |
Shock load: | 10 g / IEC 68-2-29 / 16 ms |
|