Measuring range: |
100 mm ... 400 mm, 6 % ... 90 % remission |
Resolution: |
75 µm 1) |
Repeatability: |
225 µm 2) 3) 4) 5) |
Linearity: |
± 750 µm 6) 7) 8) 9) |
Response time 10): |
2 ms / 15 ms / 50 ms |
Measuring frequency: |
1.3 kHz |
Light source: |
Laser, red |
Typ. light spot size (distance): |
1.8 mm x 3.5 mm (250 mm) |
Additional function: |
Automatic sensitivity adjustment, Teach-in of switching output, Invertable switching output, Averaging 1 ... 64x, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd) |
Laser class: |
2 (EN 60825-1) 11) |
Interfaces |
Switching output 1): |
2 x PNP (100 mA) |
Multifunctional input (MF) 2): |
1 x MF |
Mechanics/electronics |
Connection type: |
Male connector, M12, 8-pin |
Supply voltage Vs 1): |
DC 12 V ... 24 V |
Power consumption 2): |
≤ 2.88 W |
Warm-up time: |
≤ 5 min |
Indication: |
Distance bar graph, up to 8 status LEDs |
Weight: |
70 g |
Housing material: |
PBT housing with PMMA lens |
Ambient data |
Enclosure rating: |
IP 67 |
Protection class: |
III |
Ambient temperature: |
Operation: -10 ... +40 °C, Storage: -20 ... +60 °C |
Temperature drift: |
± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
Typ. ambient light safety: |
Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx |
Vibration resistance: |
10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
Shock resistance: |
50 G (x-, y-, z-axis 3 times each) |
Relative humidity (not condensing): |
35 % ... 95 % |