Product Summary

Displacement Sensor OD250-150N152 CMOS, Measuring Range 250+/-150 mm
Manufacturer: Sick
Manufacturer part number: 6028095
SKU: 151391
Weight(kg): 0.2940

Click here to check availability

Pricing - Condition Manufacturer New

£1,091.80 excl VAT
£1,051.95 excl VAT

Downloads

  • Many measurement ranges from 26 mm ... 34 mm to 100 mm ... 400 mm
  • CMOS receiving element for accurate measurement independent of surface
  • High-visibility LC display on the device
  • Laser technology for measurement of very small objects
  • Tough and compact stand-alone device
  • Your benefits

  • Reliably measure targets regardless of color or reflectivity, minimizing machine downtime
  • Fast, cost-effective setup due to easyto-read LC display
  • Less wiring ensures low installation cost due to its compact, stand-alone design
  • Tough, metal housing for reliable operation and reduced machine downtime
  • Non-contact measurement enables quality inspection during production
  • 100% inspection with optical distance sensors ensures consistent high product quality

Performance
Measurement range:100 mm ... 400 mm, 6 % ... 90 % remission
Resolution:75 µm 1) 2)
Repeatability:225 µm 3)
Linearity:± 6 mm 4)
Response time 5):2 ms
Measuring frequency:1 kHz
Light source:Laser, red
Typ. light spot size (distance):1.5 mm x 3 mm (250 mm)
Additional function:3 memory banks, Automatic sensitivity adjustment, Teach-in of analog output, Teach-in of switching output, Set hysteresis, Manual sensitivity adjustment, Averaging function 1 ... 1,024x, Switching mode: distance to object (DtO), Switching mode: window (Wnd)
Laser class:2 (EN 60825-1) 6)
1) 4) 6 % ... 90 % remission  2) Averaging function set to: 64  3) Averaging function set to: 64; constant ambient conditions  5) Automatic sensitivity adjustment = 15 ms  6) Wavelength: 650 nm, max. output: 1 mW  
Interfaces
Output type 1):1 x NPN (100 mA)
Analog output:1 x 4 mA ... 20 mA (≤ 300 Ω)
Teach input:1 x ET
Trigger input:1 x trigger
1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS  
Mechanics/electronics
Connection type:Cable, 2 m
Supply voltage Vs 1):DC 12 V ... 24 V
Power consumption 2):≤ 2.88 W
Warm-up time:≤ 5 min
Indication:LC display
Weight:200 g 3)
Housing material:Zinc housing with glass lens
1) DC 12 V (-5 %) ... DC 24 V (+10 %)  2) Without load, with current output  3) 300 g with cable  
Ambient data
Enclosure rating:IP 67
Protection class:III
Ambient temperature:Operation: -10 ... 40 °C, Storage: -20 ... 60 °C
Temperature drift:± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Typ. ambient light safety:Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx
Vibration resistance:10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance:50 G (x-, y-, z-axis 3 times each)
Relative humidity (not condensing):35 % ... 85 %