Performance | Measurement range: | 100 mm ... 400 mm, 6 % ... 90 % remission |
Resolution: | 75 µm 1) 2) |
Repeatability: | 225 µm 3) |
Linearity: | ± 6 mm 4) |
Response time 5): | 2 ms |
Measuring frequency: | 1 kHz |
Light source: | Laser, red |
Typ. light spot size (distance): | 1.5 mm x 3 mm (250 mm) |
Additional function: | 3 memory banks, Automatic sensitivity adjustment, Teach-in of analog output, Teach-in of switching output, Set hysteresis, Manual sensitivity adjustment, Averaging function 1 ... 1,024x, Switching mode: distance to object (DtO), Switching mode: window (Wnd) |
Laser class: | 2 (EN 60825-1) 6) |
|
Interfaces |
Output type 1): | 1 x NPN (100 mA) |
Analog output: | 1 x 4 mA ... 20 mA (≤ 300 Ω) |
Teach input: | 1 x ET |
Trigger input: | 1 x trigger |
|
Mechanics/electronics |
Connection type: | Cable, 2 m |
Supply voltage Vs 1): | DC 12 V ... 24 V |
Power consumption 2): | ≤ 2.88 W |
Warm-up time: | ≤ 5 min |
Indication: | LC display |
Weight: | 200 g 3) |
Housing material: | Zinc housing with glass lens |
|
Ambient data |
Enclosure rating: | IP 67 |
Protection class: | III |
Ambient temperature: | Operation: -10 ... 40 °C, Storage: -20 ... 60 °C |
Temperature drift: | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
Typ. ambient light safety: | Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx |
Vibration resistance: | 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
Shock resistance: | 50 G (x-, y-, z-axis 3 times each) |
Relative humidity (not condensing): | 35 % ... 85 % |
|