Select Store:
Select Currency:

Sick PBT-RB016SU1SEFAMA0Z (6042370)

Product Summary

PRESSURE SENSOR
Manufacturer: Sick
Manufacturer part number: 6042370
SKU: 186162
Weight(kg): 0.9990

Click here to check availability

Pricing - Condition Manufacturer New

£111.27 excl VAT
£105.71 excl VAT
  • Gauge pressure measurement ranges from 0 ... 1 bar up to 0 … 600 bar
  • A large variety of available process connections
  • No moving parts: No mechanical wear, fatigue-proof, maintenance-free
  • Circularly welded, hermetically sealed stainless steel membrane
  • Output signal 4 … 20 mA, 0 … 5 V or 0 … 10 V
  • Electrical connection M12x1, L-connector acc. to DIN 175301-803 A or flying leads
  • Your benefits

  • Compact size takes up less space
  • Simple and cost-saving installation
  • Available in a wide selection of configurations, enabling a perfect match to individual customer requirements
  • Robust design enables higher reliability
  • Excellent price/performance ratio

Features
Pressure type:Gauge pressure
Measuring range:0 bar ... 16 bar
Process temperature:-30 °C ... 100 °C
CE-conformity:
Output signal:4...20 mA
Performance
Accuracy:<= +/- 1 % (of span)
Non-linearity:± 0.25 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2)
Response time:< 4 ms
Long-term drift/one-year stability:<= 0.1 % of span according to IEC 61298-2
Rated temperature range:0 °C ... 80 °C
Service life:10 Mio. max. life cycles
Non-repeatability:<= 0.1 % of span
Adjustment accuracy of zero signal:<= 0.5 typ., 0.8 % max. % of span
Hysteresis:± 0.16 % 1)
Signal noise:<= 0.3 % of span
1) Of span  
Mechanics/electronics
Process connection:7/16-20 UNF SAE #4 J514 male
Wetted parts:Pressure Connection: 316L, Pressure sensor: 316L (for measurement ranges from 0 bar ... 10 bar rel: 13-8 PH)
Seal:FPM/FKM
Pressure port:Standard
Housing material:316L
Enclosure rating:IP 67
Connection type:M12 x 1, 4-pin, IP 67
Supply voltage:8 V DC ... 30 V DC
Power consumption:Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output
Electrical safety:Short-circuit protection: QA towards M, Reference conditions: According to IEC 61298-1, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M
Protection class III:
Weight sensor:Ca. 80 g
Isolation voltage:500 V DC 1)
CE-conformity:Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EEC, EN 61326-2-3
1) For power supply use a circuit with energy limitation (EN/UL/IEC 61010-1. section 9.3) with the following maximum values for the current: L+ = 30 V (DC): 5 A. Provide a separate switch for the external power supply. Alternative for North America: The connection may also be made to "Class 2 Circuits" or "Class 2. Power Units" according to CEC (Canadian Electrical Code) or NEC (National Electrical Code)  
Ambient data
Storage temperature:0 °C ... 80 °C
Ambient temperature:0 °C ... 80 °C
Shock load:500 g according to IEC 60068-2-27 (mechanical shock)
Vibration load:10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional
Relative humidity:45 % ... 75 %
Products specifications
Manufacturer category Sick PBT
Manufacturer Sick