Features | Pressure type: | Gauge pressure |
Measurement range: | 0 bar ... 60 bar |
Process temperature: | -30 °C ... 100 °C |
Rated temperature: | 0 °C ... 80 °C |
CE-conformity: | ![](../images/hook2.gif) |
Output signal: | 4...20 mA |
|
Performance |
Accuracy: | <= +/- 0.5 % (of span) |
Non-linearity: | ± 0.2 % (Best Fit Straight Line (BFSL)) |
Response time: | <= 1 ms (≤ 10 ms at medium temperatures below < -30°C for pressure ranges up to 25 bar or with flush-mounted membrane) |
|
Mechanics/electronics |
Process connection: | G 1/2 B flush-mounted with O-ring |
Wetted parts: | With flush-mounted diaphragm: Stainless steel O-ring: NBR (O-ring made of FPM/FKM for version with flush-mounted membrane with integrated cooling element), FPM/FKM optional |
Seal: | With flush-mounted membrane: wetted parts: CrNi-steel + NBR O-Ring |
Pressure port: | Front-flush membrane |
Housing material: | Stainless steel |
Enclosure rating: | IP 67 |
Connection type: | M12x1, 4-pin |
Supply voltage: | 10 V DC ... 30 V DC |
Electrical safety: | Short-circuit protection: QA towards M, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M |
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) |
Protection class III: | ![](../images/hook2.gif) |
|
Ambient data |
Ambient temperature: | -20 °C ... 80 °C |
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) |
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
|