Select Store:
Select Currency:

Sick S10B-9011BA (1042266)

Product Summary

S100 Laser scanner Standard S10B-9011BA
Manufacturer: Sick
Manufacturer part number: 1042266
SKU: 182724
Weight(kg): 1.1400

Click here to check availability

Pricing - Condition Manufacturer New

£2,352.70 excl VAT
£2,266.00 excl VAT
    • Small, lightweight and economical measurement system
    • Field evaluation using intelligent algorithms
    • Parameter setting interface is accessible from the front while the device is mounted

Your benefits

  • Simple mounting due to lightweight design
  • No wiring between sender and receiver
  • Rapid diagnostics due to a 7-segment display, reducing downtime
  • Connectivity in both back and bottom of device provide improved installation flexibility
  • 270° scanning angle makes it ideal for both horizontal and vertical applications

 

Features

Field of application: Indoor
Version: Short Range
Light source: Infrared (905 nm)
Laser class: 1 (21CFR 1040.10, 21CFR 1040.11, IEC60825-1:2001)
Field of view: 270 °
Scanning frequency: 25 Hz
Angular resolution: 0.5 °
Operating range: 0 m ... 10 m
Max. range with 10 % reflectivity: 4.5 m
 
Performance
Detectable object shape: Almost any (diameter: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (selectable))
Integrated application: Field evaluation
Number of field sets: 1 field pair (2 fields)
Simultaneous processing cases: 1 (2 fields)
 
Interfaces
Serial (RS-232):
Ethernet: -
CAN bus:
Protocol (CAN bus): CANopen
PROFIBUS DP: -
PROFINET: -
DeviceNet: -
Switching inputs: 1
Switching outputs: 2
Optical indicators: 1 7-segment display (contamination warning, initial condition)
 
Mechanics/electronics
Electrical connection: 1 system plug with screw terminal block (accessory)
Operating voltage: 16.8 V DC ... 30 V DC
Power consumption: 8 W
Housing color: Black (RAL 9005)
Enclosure rating: IP 65 (EN 60529, Section 14.2.5)
Protection class: II (VDE 0106, EN50178)
Weight: 1.2 kg, without connecting cables
Dimensions: 105 mm x 102 mm x 152 mm
Output current: ≤ 250 mA
 
Ambient data
Object remission: 1.8 % ... > 1,000 % (reflectors)
Ambient operating temperature: -10 °C ... +50 °C
Storage temperature: -30 °C ... +70 °C
 
General notes
Note on use: Not suitable for personnel protection
 
Products specifications
Manufacturer category Sick LMS100
Manufacturer Sick