Field of application: |
Indoor |
Version: |
Short Range |
Light source: |
Infrared (905 nm) |
Laser class: |
1 (21CFR 1040.10, 21CFR 1040.11, IEC60825-1:2001) |
Field of view: |
270 ° |
Scanning frequency: |
25 Hz |
Angular resolution: |
0.5 ° |
Operating range: |
0 m ... 10 m |
Max. range with 10 % reflectivity: |
4.5 m |
Performance |
Detectable object shape: |
Almost any (diameter: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (selectable)) |
Integrated application: |
Field evaluation |
Number of field sets: |
1 field pair (2 fields) |
Simultaneous processing cases: |
1 (2 fields) |
Interfaces |
Serial (RS-232): |
 |
Ethernet: |
- |
CAN bus: |
 |
Protocol (CAN bus): |
CANopen |
PROFIBUS DP: |
- |
PROFINET: |
- |
DeviceNet: |
- |
Switching inputs: |
1 |
Switching outputs: |
2 |
Optical indicators: |
1 7-segment display (contamination warning, initial condition) |
Mechanics/electronics |
Electrical connection: |
1 system plug with screw terminal block (accessory) |
Operating voltage: |
16.8 V DC ... 30 V DC |
Power consumption: |
8 W |
Housing color: |
Black (RAL 9005) |
Enclosure rating: |
IP 65 (EN 60529, Section 14.2.5) |
Protection class: |
II (VDE 0106, EN50178) |
Weight: |
1.2 kg, without connecting cables |
Dimensions: |
105 mm x 102 mm x 152 mm |
Output current: |
≤ 250 mA |
Ambient data |
Object remission: |
1.8 % ... > 1,000 % (reflectors) |
Ambient operating temperature: |
-10 °C ... +50 °C |
Storage temperature: |
-30 °C ... +70 °C |
General notes |
Note on use: |
Not suitable for personnel protection |