Select Store:
Select Currency:

Sick S30A-4011DA (1028936)

Product Summary

Safety laser scanner S3000S Professional S30A-4011DA Short Range 4 m protective field range 8 protective/warning fields
Manufacturer: Sick
Manufacturer part number: 1028936
SKU: 182733
Weight(kg): 3.7470

Click here to check availability

Pricing - Condition Manufacturer New

£4,365.69 excl VAT
£4,147.41 excl VAT
  • 4 m protective field range
  • Eight switchable field sets (eight protective fields, 16 warning fields)
  • Configuration memory integrated in the system plug
  • EFI interface for safe SICK device communication
  • Incremental encoder inputs for speed-dependent field switching
  • Measured data output via RS-422
  • Simultaneous monitoring of up to four protective fields
  • Monitoring of the maximum speed of an AGV
  • Your benefits

  • Largest protective field range in the market increases the variety of application possibilities
  • Variety of field sets ensures safety and productivity when protecting vehicles or moving machine parts
  • Quick recommissioning via configuration memory
  • Expandable modular system, simple cabling and additional functions such as the simultaneous monitoring of up to four protective fields using SICK safety controllers with EFI
  • The correct protective field at any speed avoids unnecessary stops.
  • Personnel protection and navigation support in one device
  • Easy installation, commissioning and maintenance for stationary and mobile applications
  • Decades of proven safety technology guarantee maximum reliability and productivity - even under difficult conditions

Applications
Hazardous area protection (vertical):
Access protection (vertical):
Hazardous area protection (horizontal):
Functions
Number of simultaneously monitored protective fields:≤ 4 1)
Static protective field switching:
Incremental encoder inputs:
External device monitoring (EDM):
Integrated configuration memory:
Expanded measured data output (CMS, RS-422):-
Measured data output (RS-422):
Safe SICK device communication via EFI/SDL:
1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway.  
Technical data
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529)
Protection class:II (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... 50 °C
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Weight:3.3 kg
Scan angle:190 °
Protective field range:4 m
Maximum warning field range:49 m
Number of field sets:8 1)
Number of monitoring cases:16
Response time:60 ms 2)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Distance measuring range:49 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:System plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Number of EDM inputs:1
Number of reset-/restart inputs:1
Number of static control inputs:4
Number of static control inputs with EFI:5 3)
Number of dynamic control inputs:2 4)
Number of safe outputs:2, Safety outputs (OSSD)
Number of application diagnostic outputs:3 5)
Maximum output current:500 mA
Configuration and diagnostics interface:RS-232
Data interface:RS-422
1) 1 field set = 1 protective field and 2 warning fields  2) Depending on basic response time and multiple sampling  3) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise four.  4) Two of the static swichting signals can be used either as dynamic or as static switching signals.  5) Freely programmable, e.g., warning field, contamination, reset required  
Products specifications
Manufacturer category Sick S3000S
Manufacturer Sick