Select Store:
Select Currency:

Sick S30A-4111CP (1045650)

Product Summary

Safety laser scanner S3000S PROFINET IO Advanced S30A-4111CP Short Range 4 m protective field range 4 protective/warning fields
Manufacturer: Sick
Manufacturer part number: 1045650
SKU: 182735
Weight(kg): 3.9810

Click here to check availability

Pricing - Condition Manufacturer New

£4,338.43 excl VAT
£4,121.51 excl VAT

Downloads

  • Direct integration in PROFINET IO safe bus system
  • 4 m protective field range
  • Four switchable field sets (four protective fields, four warning fields)
  • Remote diagnostics and configuration through safety controller
  • Managed 2-port switch for RJ45 plug connector
  • Configuration memory integrated in the system plug
  • Simultaneous monitoring of two protective fields
  • Your benefits

  • Reliable, fault-tolerant communication with PLC controller using state-of-the-art fiber-optic technology.
  • Efficient, cost-effective protection - networked through direct connection to PROFINET IO networks
  • Rapid diagnosis by means of remote access prevents downtimes
  • Standardized integration in PLC controllers, thanks to GSDML generic station description
  • Largest protective field range in the market increases the variety of application possibilities
  • Quick recommissioning via configuration memory
  • Easy installation, commissioning and maintenance for stationary and mobile applications
  • Decades of proven safety technology guarantee maximum reliability and availability - even under difficult conditions

Applications
Hazardous area protection (vertical):
Access protection (vertical):
Hazardous area protection (horizontal):
Functions
Number of simultaneously monitored protective fields:2
Static protective field switching:-
Incremental encoder inputs:-
External device monitoring (EDM):-
Integrated configuration memory:
Expanded measured data output (CMS, RS-422):-
Measured data output (RS-422):-
Safe SICK device communication via EFI/SDL:-
Technical data
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529)
Protection class:III (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... 50 °C
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Weight:3.3 kg
Scan angle:190 °
Protective field range:4 m
Maximum warning field range:49 m
Number of field sets:4 1)
Number of monitoring cases:4
Response time:60 ms 2)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Distance measuring range:49 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:Copper conductor (2 sockets for RJ-45 push-pull plug), system plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Configuration and diagnostics interface:RS-232
Device properties:PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2
PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4
Cycle time 4, 8, 16, 32 ms, etc.
GSDML according to GSDML specification V2.25
Switch properties:Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q - Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Port properties:Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-TX
Conformance:Conformance Class B
Topology support:SNMP, MIB-2, LLDP nach IEEE 802.1AB
MRP client support
Diagnostics:Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Interfaces for configuration and diagnostics using CDS:TCP port 9000 and UDP port 30718
RS-232
Functions that are not supported:Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
1) 1 field set = 1 protective field and 2 warning fields  2) Depending on basic response time and multiple sampling  
Products specifications
Manufacturer category Sick S3000S
Manufacturer Sick