Hazardous area protection (vertical): |
|
Access protection (vertical): |
|
Hazardous area protection (horizontal): |
|
Functions |
Number of simultaneously monitored protective fields: |
2 |
Static protective field switching: |
- |
Incremental encoder inputs: |
- |
External device monitoring (EDM): |
- |
Integrated configuration memory: |
|
Expanded measured data output (CMS, RS-422): |
- |
Measured data output (RS-422): |
- |
Safe SICK device communication via EFI/SDL: |
- |
Technical data |
Laser class: |
1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Enclosure rating: |
IP 65 (EN 60529) |
Protection class: |
III (EN 50178) |
Type: |
Type 3 (IEC 61496) |
Safety integrity level: |
SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: |
Category 3 (EN ISO 13849) |
Performance level: |
PL d (EN ISO 13849) |
PFHd: |
8.0 * 1E-08 (EN ISO 13849) |
TM (mission time): |
20 a (EN ISO 13849) |
Ambient operating temperature: |
-10 °C ... 50 °C |
Dimensions (W x H x D): |
155 mm x 185 mm x 160 mm |
Weight: |
3.3 kg |
Scan angle: |
190 ° |
Protective field range: |
5.5 m |
Maximum warning field range: |
49 m |
Number of field sets: |
4 1) |
Number of monitoring cases: |
4 |
Response time: |
60 ms 2) |
Resolution: |
30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
Distance measuring range: |
49 m |
Number of multiple samplings: |
Configurable 2 ... 16 |
Electrical connection: |
Copper conductor (2 sockets for RJ-45 push-pull plug), system plug with or without connecting cable |
Supply voltage: |
16.8 V DC, 24 V DC, 28.8 V DC |
Configuration and diagnostics interface: |
RS-232 |
Device properties: |
PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2 PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4 Cycle time 4, 8, 16, 32 ms, etc. GSDML according to GSDML specification V2.25 |
Switch properties: |
Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q - Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on "Cut-through" Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer |
Port properties: |
Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX |
Conformance: |
Conformance Class B |
Topology support: |
SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support |
Diagnostics: |
Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 |
Interfaces for configuration and diagnostics using CDS: |
TCP port 9000 and UDP port 30718 RS-232 |
Functions that are not supported: |
Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control |