Select Store:
Select Currency:

Sick S30B-2011DB (1041152)

Product Summary

Safety laser scanner S300 Professional CMS S30B-2011DB 2m protective field range 4 protective/warning fields
Manufacturer: Sick
Manufacturer part number: 1041152
SKU: 182754
Weight(kg): 1.1820

Click here to check availability

Pricing - Condition Manufacturer New

Call for pricing
Applications
Hazardous area protection (vertical):
Access protection (vertical):
Hazardous area protection (horizontal):
Functions
Static protective field switching:
Incremental encoder inputs:
External device monitoring (EDM):
Integrated configuration memory:
Expanded measured data output (CMS, RS-422):
Measured data output (RS-422):
Safe SICK device communication via EFI/SDL:
Technical data
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529)
Protection class:II (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-10 °C ... 50 °C
Dimensions (W x H x D):102 mm x 152 mm x 106 mm
Weight:1.2 kg
Scan angle:270 °
Protective field range:2 m
Maximum warning field range:8 m
Number of field sets:4
Response time:80 ms
Resolution:30 mm, 40 mm, 50 mm, 70 mm, configurable
Distance measuring range:30 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:System plug with or without connecting cable
Supply voltage:16.8 V DC, 24 V DC, 30 V DC
Number of EDM inputs:1
Number of reset-/restart inputs:1
Number of static control inputs:2
Number of stand-by inputs:1
Number of dynamic control inputs:2
Number of safe outputs:2, Safety outputs (OSSD)
Number of warning field outputs:1
Number of application diagnostic outputs:≤ 1
Maximum output current:250 mA
Configuration and diagnostics interface:RS-232
Data interface:RS-422
Products specifications
Manufacturer category Sick S300
Manufacturer Sick