Hazardous area protection (vertical): |
|
Access protection (vertical): |
|
Hazardous area protection (horizontal): |
|
Functions |
Static protective field switching: |
|
Incremental encoder inputs: |
|
External device monitoring (EDM): |
|
Integrated configuration memory: |
|
Expanded measured data output (CMS, RS-422): |
|
Measured data output (RS-422): |
|
Safe SICK device communication via EFI/SDL: |
|
Technical data |
Laser class: |
1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Enclosure rating: |
IP 65 (EN 60529) |
Protection class: |
II (EN 50178) |
Type: |
Type 3 (IEC 61496) |
Safety integrity level: |
SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: |
Category 3 (EN ISO 13849) |
Performance level: |
PL d (EN ISO 13849) |
PFHd: |
8.0 * 1E-08 (EN ISO 13849) |
TM (mission time): |
20 a (EN ISO 13849) |
Ambient operating temperature: |
-10 °C ... 50 °C |
Dimensions (W x H x D): |
102 mm x 152 mm x 106 mm |
Weight: |
1.2 kg |
Scan angle: |
270 ° |
Protective field range: |
2 m |
Maximum warning field range: |
8 m |
Number of field sets: |
16 1) |
Number of monitoring cases: |
32 |
Response time: |
80 ms 2) |
Resolution: |
30 mm, 40 mm, 50 mm, 70 mm, configurable |
Distance measuring range: |
30 m |
Number of multiple samplings: |
Configurable 2 ... 16 |
Electrical connection: |
System plug with or without connecting cable |
Supply voltage: |
16.8 V DC, 24 V DC, 30 V DC |
Number of universal I/Os: |
5 3) |
Number of EDM inputs: |
1 4) |
Number of reset-/restart inputs: |
1 5) |
Number of static control inputs: |
3 6) |
Number of static control inputs with EFI: |
5 7) |
Number of stand-by inputs: |
1 |
Number of dynamic control inputs: |
2 8) |
Number of safe outputs: |
2, Safety outputs (OSSD) |
Number of application diagnostic outputs: |
3 9) |
Maximum output current: |
250 mA |
Configuration and diagnostics interface: |
RS-232 |
Data interface: |
RS-422 |