Select Store:
Select Currency:

Sick S31A-7011CA (1041648)

Product Summary

Sick S31A-7011CA (1041648)
Manufacturer: Sick
Manufacturer part number: 1041648
SKU: 188288
Click here to check availability

Pricing - Condition Manufacturer New

£5,925.10 excl VAT
£5,628.84 excl VAT
  • Designed and certified for temperatures down to -30 °C
  • Modified housing with integrated temperature controller
  • IP 67 enclosure rating
  • 7 m protective field range
  • Four switchable field sets (four protective fields, eight warning fields)
  • EFI interface for safe SICK device communication
  • Selectable resolution for hand, leg or body detection
  • Contour as reference for vertical applications
  • Your benefits

  • First safety laser scanner available on the market which can be used at temperatures as low as -30 °C.
  • Hazard area, hazard point, access or vehicle protection in cold areas.
  • Largest protective field range in the market increases the variety of application possibilities
  • Expandable modular system, simple cabling and additional functions such as the simultaneous monitoring of up to four protective fields using SICK safety controllers with EFI
  • Easy installation, commissioning and maintenance for stationary and mobile applications
  • Decades of proven safety technology guarantee maximum reliability and productivity – even under difficult conditions

Applications
Hazardous area protection (vertical):
Access protection (vertical):
Hazardous area protection (horizontal):
Functions
Number of simultaneously monitored protective fields:≤ 4 1)
Static protective field switching:
Incremental encoder inputs:-
External device monitoring (EDM):-
Integrated configuration memory:-
Expanded measured data output (CMS, RS-422):-
Measured data output (RS-422):-
Safe SICK device communication via EFI/SDL:
1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway.  
Technical data
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating:IP 65 (EN 60529), IP 67 (EN 60529)
Protection class:II (EN 50178)
Type:Type 3 (IEC 61496)
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
Performance level:PL d (EN ISO 13849)
PFHd:8.0 * 1E-08 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Ambient operating temperature:-30 °C ... 50 °C
Dimensions (W x H x D):351 mm x 265 mm x 221 mm
Weight:9 kg
Scan angle:180 °
Protective field range:7 m
Maximum warning field range:49 m
Number of field sets:4
Number of monitoring cases:4
Response time:60 ms 1)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
Distance measuring range:49 m
Number of multiple samplings:Configurable 2 ... 16
Electrical connection:System plug
Supply voltage scanner:17.5 V DC, 24 V DC, 28.8 V DC
Supply voltage heating:16.8 V DC, 24 V DC, 28.8 V DC
Number of static control inputs:2
Number of static control inputs with EFI:5 2)
Number of safe outputs:2, Safety outputs (OSSD)
Number of application diagnostic outputs:2 3)
Maximum output current:500 mA
Configuration and diagnostics interface:RS-232
1) Depending on basic response time and multiple sampling  2) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise two.  3) Freely programmable, e.g., warning field, contamination, reset required  
Products specifications
Manufacturer category Sick S3000S
Manufacturer Sick