Applications | Hazardous area protection (vertical): | |
Access protection (vertical): | |
Hazardous area protection (horizontal): | |
|
Functions |
Static protective field switching: | |
Incremental encoder inputs: | - |
External device monitoring (EDM): | - |
Integrated configuration memory: | - |
Expanded measured data output (CMS, RS-422): | - |
Measured data output (RS-422): | - |
Safe SICK device communication via EFI/SDL: | |
|
Technical data |
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | III (EN 50178) |
Type: | Type 3 (IEC 61496) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
Category: | Category 3 (EN ISO 13849) |
Performance level: | PL d (EN ISO 13849) |
PFHd: | 8.0 * 1E-08 (EN ISO 13849) |
TM (mission time): | 20 a (EN ISO 13849) |
Ambient operating temperature: | -10 °C ... 50 °C |
Dimensions (W x H x D): | 102 mm x 116 mm x 105 mm |
Weight: | 0.8 kg, without connecting cables |
Scan angle: | 270 ° |
Protective field range: | 2 m |
Maximum warning field range: | 8 m |
Number of field sets: | 16 1) |
Response time: | 80 ms 2) |
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, configurable |
Distance measuring range: | 30 m |
Number of multiple samplings: | Configurable 2 ... 16 |
Electrical connection: | Cable, 250 mm, with male connector M12, 7-pin |
Supply voltage: | 16.8 V DC, 24 V DC, 30 V DC |
Number of static control inputs with EFI: | 5 3) |
Number of stand-by inputs: | 1 4) |
Number of outputs: | Depends on the configuration of the connected EFI device |
Configuration and diagnostics interface: | RS-232 |
|