Functions | External device monitoring (EDM): | - |
Self-testing: |  |
|
Technical data |
Safety integrity level: | SILCL2 (EN 62061) |
Category: | Category 3 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 4.3 * 1E-08 (EN ISO 13849) 8.8 * 1E-08 (EN ISO 13849) 1) 2) |
TM (mission time): | 20 a (EN ISO 13849) 8 a (EN ISO 13849) 3) 4) |
Classification in compliance with IEC/EN 60947-5-3: | PDF-M |
Housing material: | Plastic PA6.6 |
Enclosure rating: | IP 20 (EN 60529) |
Protection class: | III (EN 50178) |
Ambient operating temperature: | 0 °C ... 55 °C |
Connection type: | Plug-in terminals |
Type of output: | Relays |
Number of safe outputs (N/O): | 2 |
Response time: | 180 ms |
Supply voltage typical, from, to: | 24 V DC, 21 V DC, 27 V DC |
Usage category: | AC-12/DC-12, AC-14/DC-13 (EN 60947-5-2) |
Rated operating current (voltage): | 0.3 A (60 V AC) 50 Hz 6 A (30 V AC) 50 Hz 0.3 A (60 V DC) 6 A 30 V DC (2 A) 30 V AC 50 Hz (3 A) 24 V DC |
Mechanical life (relay contacts): | 10* 1E 06 switching cycles |
Number of non-contact safety switches: | 1 |
Type of connectable sensors: | T4000 DNBC |
Status display: |  |
Weight: | 0.327 kg |
ATEX approval: |  |
|