Select Store:
Select Currency:

Sick TCT-1AAGE1006MZ (6043218)

Product Summary

TEMPERATURE SENSOR
Manufacturer: Sick
Manufacturer part number: 6043218
SKU: 186556
Weight(kg): 0.9990

Click here to check availability

Pricing - Condition Manufacturer New

£180.46 excl VAT
£171.44 excl VAT
  • Pt100 element, accuracy class A according to IEC 60751
  • Measuring ranges -50 °C ... 150 °C and -50 °C … 250 °C
  • Wetted parts made from corrosion resistant stainless steel 316L
  • Integrated transmitter with output signal 4 … 20 mA (2-wire)
  • Measurement accuracy <= 0.2 % of span
  • Various mechanical adaptations and insertion lengths, also available with thermowell
  • Circular connector M12x1 (IP 67) or L-connector according to DIN EN 175301-803 A (IP 65)
  • Your benefits

  • Reliable operation through rugged design and high-quality materials
  • Good long-term stability, accuracy and linearity
  • Quick and safe installation
  • Convenient system integration through compact dimensions and industry-standard output signals
  • Optimal solutions for individual requirements

Features
Measuring range:-50 °C ... 150 °C
Sensor element:Pt100
Signal output and maximum ohmic load RA:4 mA ... 20 mA, 2-wire (RA <= (L+ - 9 V) / 0.023 A [Ohm])
Performance
Accuracy of sensor element:Class A according to IEC 60751
Transmitter accuracy:≤ ± 0.2 % of span
Transmitter linearity:≤ 0.1 % of span
Mechanics/electronics
Process connection:Thread G 1/2 B
Insertion length/diameter of probe:100 mm / 6 mm
Housing material:Stainless steel 1.4571
Wetted parts:Stainless steel 1.4571
Electrical connection/enclosure rating 1):Plug M12 x 1, 4-pin, IP 67
Measuring current:0.3 mA ... 1 mA
Electrical safety:Protection class: III, dielectric strength: 500 V, reverse polarity protection: L+ towards M
Weight:Ca. 145 g (depending on configuration)
Supply voltage:10 V DC ... 36 V DC for variant with transmitter 4 mA ... 20 mA
Protection class III:
CE-conformity:2004/108/EC, EN 61326-2-3
Pressure resistance:Max. 120 bar
1) Enclosure rating IP per IEC 60529. The enclosure rating classes specified only apply while the pressure transmitter is connected with female connectors  that provide the corresponding enclosure rating.  
Ambient data
Ambient temperature:-40 °C ... 85 °C
Storage and transport temperature:-40 °C ... 85 °C
Shock resistance according to IEC 60751:500 g
Vibration resistance according to IEC 60751:3 g
Products specifications
Manufacturer category Sick TCT
Manufacturer Sick