Features | Measuring range: | -50 °C ... 150 °C |
Sensor element: | Pt100 |
Signal output and maximum ohmic load RA: | 4 mA ... 20 mA, 2-wire (RA <= (L+ - 9 V) / 0.023 A [Ohm]) |
|
Performance |
Accuracy of sensor element: | Class A according to IEC 60751 |
Transmitter accuracy: | ≤ ± 0.2 % of span |
Transmitter linearity: | ≤ 0.1 % of span |
|
Mechanics/electronics |
Process connection: | Thread 1/2'' NPT |
Insertion length/diameter of probe: | 100 mm / 6 mm |
Housing material: | Stainless steel 1.4571 |
Wetted parts: | Stainless steel 1.4571 |
Electrical connection/enclosure rating 1): | Plug M12 x 1, 4-pin, IP 67 |
Measuring current: | 0.3 mA ... 1 mA |
Electrical safety: | Protection class: III, dielectric strength: 500 V, reverse polarity protection: L+ towards M |
Weight: | Ca. 145 g (depending on configuration) |
Supply voltage: | 10 V DC ... 36 V DC for variant with transmitter 4 mA ... 20 mA |
Protection class III: | |
CE-conformity: | 2004/108/EC, EN 61326-2-3 |
Pressure resistance: | Max. 120 bar |
|
Ambient data |
Ambient temperature: | -40 °C ... 85 °C |
Storage and transport temperature: | -40 °C ... 85 °C |
Shock resistance according to IEC 60751: | 500 g |
Vibration resistance according to IEC 60751: | 3 g |
|