  • Pt100, accuracy class A (IEC 60751)
  • Measuring ranges -50 °C ... +150 °C and -50 °C … +250 °C
  • Sensor probe spring-loaded in thermowell
  • Wetted parts: Corrosion-resistant stainless steel 316L/1.4435, Ra = 0.8 µm
  • Hygienic process connections
  • Pt100 (4-wire) or 4 mA … 20 mA (2-wire)
  • Round connector M12 x 1
  • Your benefits

  • The sensor can be exchanged without opening the process, providing high equipment availability and minimizing hygienic risks
  • Safe hygienic operation: Wetted parts are made from high-grade stainless steel, hygienically-graded surface finish, and a gap- and crevice-free design
  • Rugged: Connection housing is easily cleaned and splash water proof
  • Quick and safe installation
  • Very good long-term stability, accuracy and linearity
  • Quick response time
  • Optimal solutions for individual requirements due to versatile configurability

Features
Measurement range:-50 °C ... 150 °C
Sensor element:Pt100
Output signal:Pt100, 4-wire
Performance
Accuracy of sensor element:Class A according to IEC 60751
Transmitter accuracy:≤ ± 0.2 % of span
Transmitter linearity:≤ ± 0.1 % of span
Response time:Response time t50: ≤ 4.7 s
response time t90: ≤ 12.2 s 1)
1) Depending on sensor configuration, according to IEC 60751  
Mechanics/electronics
Process connection:Tri-clamp 1'', 1 ½''
Insertion length/diameter of probe:200 mm / 6 mm
Housing material:Stainless steel 1.4571 (316Ti)
Wetted parts:stainless steel 1.4435 (316L), Ra ≤ 0.8 µm
Electrical connection/enclosure rating 1):Round connector M12 x 1, 4-pin / IP 68 and IP 69K
Measuring current:0.3 mA ... 1 mA
Electrical safety:Dielectric strength: 500 V AC
Protection class: III
Protection class III:
Pressure resistance:Max. 16 bar at room temperature
1) Enclosure rating IP per IEC 60529. The enclosure rating classes specified only apply while the pressure transmitter is connected with female connectors  that provide the corresponding enclosure rating.  
Ambient data
Ambient temperature:-40 °C ... 85 °C
Storage and transport temperature:-40 °C ... 85 °C
Vibration resistance according to IEC 60751:3 g
Shock resistance:According to IEC 60751
Relative humidity:≤ 95 %
Products specifications