Features | Measurement range: | -50 °C ... 150 °C |
Sensor element: | Pt100 |
Signal output and maximum ohmic load RA: | 4 mA ... 20 mA, 2-wire (RA ≤ (L+ - 10 V) / 0.023 A [Ohm]) |
|
Performance |
Accuracy of sensor element: | Class A according to IEC 60751 |
Transmitter accuracy: | ≤ ± 0.2 % of span |
Transmitter linearity: | ≤ ± 0.1 % of span |
Response time: | Response time t50: ≤ 3.3 s response time t90: ≤ 9.7 s 1) |
|
Mechanics/electronics |
Process connection: | Tri-clamp 1'', 1 ½'' |
Insertion length/diameter of probe: | 75 mm / 6 mm |
Housing material: | Stainless steel 1.4571 (316Ti) |
Wetted parts: | stainless steel 1.4435 (316L), Ra ≤ 0.8 µm |
Electrical connection/enclosure rating 1): | Round connector M12 x 1, 4-pin / IP 68 and IP 69K |
Electrical safety: | Dielectric strength: 500 V AC Protection class: III Reverse polarity protection: L+ towards M |
Supply voltage: | 10 V DC ... 35 V DC |
Protection class III: | |
CE-conformity: | 2004/108/EC, EN 61326-2-3 |
Pressure resistance: | max. 16 bar |
Maximum power consumption: | Ca. 30 mA |
|
Ambient data |
Ambient temperature: | -40 °C ... 85 °C |
Storage and transport temperature: | -40 °C ... 85 °C |
Vibration resistance according to IEC 60751: | 3 g |
Shock resistance: | According to IEC 60751 |
Relative humidity: | ≤ 95 % |
|