Functions | PSDI mode: |  |
Bypass: |  |
Operating mode switching: |  |
|
Technical data |
Protection class: | III (IEC 536:1976) |
Enclosure rating: | IP 20 (IEC 60529) |
Type: | Category 4 (EN ISO 13849), Type 4 (IEC 61496) |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: | Category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 15 * 1E-09 |
TM (mission time): | 20 a |
Dimensions (W x H x D): | 22.5 mm x 99 mm x 114.5 mm |
Supply voltage from, typical, to: | 19.2 V DC, 24 V DC, 28.8 V DC |
Ripple: | ≤ 10 % |
Maximum power consumption: | 110 |
Maximum switch on time: | 4 s |
Connection type: | Screw-terminal connector |
Minimum conductor cross-section: | 0.25 mm² |
Wire cross section from ... to: | 0.25 mm² ... 2.5 mm² |
Ambient operating temperature from ... to: | 0 °C ... 55 °C |
Storage temperature from ... to: | -25 °C ... 70 °C |
Air humidity from ... to: | 15 % ... 95 %, non-condensing |
Housing material: | Plastic |
System part: | Safety relays |
|