Select Store:
Select Currency:

Sick UE403-A0930 (1026287)

Product Summary

UE403-A0930, IP65 control unit for muting with M4000 Advanced series, signal connection M12 x 5 for: reset-/ override-/ belt stop-/ additional signal C1, 4 muting sensors, 1 external muting indicator lamp
Manufacturer: Sick
Manufacturer part number: 1026287
SKU: 183032
Weight(kg): 0.7680

Click here to check availability

Pricing - Condition Manufacturer New

£269.28 excl VAT
£255.82 excl VAT

Downloads

Functions
Muting (with M4000 Advanced, M4000 A/P):
Concurrence monitoring (with M4000 Advanced, A/P):
Override (with M4000 Advanced, A/P):
Monitoring total muting time (with M4000 Advanced, A/P):
Sensor gap monitoring (with M4000 Advanced, A/P):
Sensor test (with M4000 Advanced, A/P):
Partial blanking (with M4000 Advanced, A/P):
End of muting by ESPE (with M4000 Advanced, A/P):
Belt stop (with M4000 Advanced, A/P):
Number of muting sensors:4
Connection muting lamp:
Connection belt stop signal:
Connection additional signal C1:
Connection reset control switch:
Connection override control switch:
Technical data
Protection class:III (EN 50178:1998)
Enclosure rating:IP 65 (IEC 60529)
Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061) 1)
Category:Category 4 (EN ISO 13849) 2)
Performance level:PL e (EN ISO 13849) 3)
PFHd:1.0 * 1E-08 4)
TM (mission time):18 a 5)
Dimensions (W x H x D):76.5 mm x 225.2 mm x 40 mm
Supply voltage from, typical, to:19.2 V DC, 24 V DC, 28.8 V DC
Maximum power consumption:2
Type of muting sensors:inductive sensors, mechanical switches, Optical sensors, controller signals
Connection type:Socket M12 x 5
Switching voltage HIGH inputs from, typical, to:11 V DC, 24 V DC, 30 V DC
Input current HIGH from, typical, to:6 mA, 10 mA, 15 mA
Switching voltage LOW inputs from, typical, to:-30 V DC, 0 V DC, 5 V DC
Input current LOW from, typical, to:-0.5 mA, 0 mA, 1.5 mA
Supply voltage outputs from, typical, to:15 V DC, 24 V DC, 28.8 V DC
Supply current outputs for muting sensors:400 mA 6)
Supply current outputs for reset, override or C1:500 mA 7)
Switching voltage HIGH output, muting lamp, from, typical, t:15 V DC, 24 V DC, 28.8 V DC
Output current HIGH (monitored), muting lamp, from, to:Monitored, 20 mA, 400 mA 8)
Output current HIGH (not monitored), muting lamp, from, to:Not monitored, 0 mA, 400 mA 9)
Maximum output power HIGH, muting lamp:5 W
Maximum cable length to ESPE:10 m
Minimum conductor cross-section:0.34 mm²
Wire cross section from ... to:0.34 mm²
Maximum cable resistance:< 0.5 Ω (per cable)
Ambient operating temperature from ... to:-10 °C ... 55 °C
Storage temperature from ... to:-25 °C ... 70 °C
Air humidity from ... to: 15 % ... 95 %, non-condensing
Vibration resistance (checked to):5 (IEC 60068-2-6)
Oscillation frequency from ... to:10 ... 55
Shock resistance:10 g, 16 ms (IEC 60068-2-29)
Housing material:Die-cast aluminum (powder coated)
Material, connector strip:Polyamide
Mounting:flexible mounting to the M4000 Advanced or directly in the system
System part:Safety relays
1) 2) 3) 4) 5) Only in conjunction with M4000 Advanced or M4000 Advanced A/P  6) 7) Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1 in each case): max. 1000 mA  8) 9) At max. 5 W power consumption  
Products specifications
Manufacturer category Sick UE403
Manufacturer Sick