Safety integrity level: |
SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Category: |
Category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
7.9 * 1E-09 |
TM (mission time): |
20 a |
Functions |
Number of reset-/restart inputs: |
1 |
Number of external device monitoring: |
1 |
Muting: |
 |
Override: |
 |
Belt stop: |
- |
Concurrence monitoring: |
 |
Monitoring total muting time: |
 |
Sensor gap monitoring: |
 |
End of muting by ESPE: |
 |
Mechanical data |
Dimensions (W x H x D): |
22.5 mm x 96.5 mm x 120.8 mm |
Weight: |
180 g |
Electrical data |
Protection class: |
EN 61140 |
Type of supply voltage: |
PELV (electrical output circuit on UE410-4RO/UE410-2RO > 25 V AC/60 V DC), PELV or SELV (electrical output circuit on UE410-4RO/UE410-2RO < 25 V AC/60 V DC) |
Supply voltage: |
24 V DC (19.2 V DC ... 30 V DC) |
Ripple: |
≤ 3 V |
Power consumption: |
3 W |
Short-circuit protection: |
4 A gG |
Switch-on time: |
10 s |
Switch-on time of inputs: |
70 ms |
Input voltage HIGH: |
15 V DC ... 30 V DC |
Input voltage LOW: |
-5 V DC ... 5 V DC |
Input current HIGH: |
2.3 mA ... 3 mA3.6 mA |
Input current LOW: |
-2.5 mA ... 0.15 mA |
Output voltage: |
18 V DC ... 30 V DC |
Output current: |
2 A |
Muting time to operate: |
70 ms |
Tolerated muting sensor signal interrupt: |
200 ms 1) |
Total muting monitoring time: |
Activation and time adjustable 0.33 ... 60 min |
Switch-on time ENTER button: |
3 s Upon applying the supply voltage |
Type of output: |
PNP semiconductors, short-circuit protected, cross-circuit monitored |
Response time: |
≤ < 13 ms |
Number of inputs: |
1 dual-channel and 4 single-channel |
Number of outputs: |
1 dual-channel and 2 single-channel |
Number of muting sensors: |
2, 4 |
Interfaces |
Connection type: |
Cable gland |
Ambient data |
Connection type: |
Plug-in spring terminals |
Enclosure rating terminals: |
IP 20 |
Protection class housing: |
IP 40 |
Ambient operating temperature: |
-25 °C ... 55 °C |
Storage temperature: |
-25 °C ... 70 °C |
Air humidity: |
15 % ... 95 %, non-condensing |
Climate conditions according to: |
EN 61131-2 |
Electromagnetic compatibility (EMC): |
EN 61000 EN 55011 |
Vibration resistance: |
5 g, 5 Hz ... 500 Hz (EN 60068-2-6) |