Select Store:
Select Currency:

Sick UE410-MU3T50 (6026137)

Product Summary

UE410-MU3T50 Master Unit, 4 Inputs/4 Outputs, Output Delay Possible: 0-50s, Screw Terminals
Manufacturer: Sick
Manufacturer part number: 6026137
SKU: 183066
Weight(kg): 0.2370

Click here to check availability

Pricing - Condition Manufacturer New

£312.18 excl VAT
£301.25 excl VAT

Downloads

    • Two variants to choose from: main module for common applications or an expert module for muting
    • Central processing unit
    • Modularly expandable
    • 6 inputs, 4 outputs
    • Small width of 22.5 mm
    • Pluggable terminals for a fast module replacement
    • PNP outputs, each up to 2A

Your benefits

  • One module offers complete functionality of inputs and outputs up to the logic
  • Easy to expand if more inputs and outputs are required
  • Easy diagnostics via clear LED status indicators, which reduces downtime
  • Use of powerful PNP semiconductor outputs allows to remove relays

 

Safety-related parameters

Safety integrity level: SIL3 (IEC 61508)
Category: Category 4 (EN ISO 13849)
Performance level: PL e (EN ISO 13849)
PFHd: 2.5 * 1E-09
6.0 * 10-9
TM (mission time): 20 a
Stop category: 0 (EN 60204)
 
Functions
Number of reset-/restart inputs: 2
Number of external device monitoring: 2
Muting:
 
Mechanical data
Dimensions (W x H x D): 22.5 mm x 96.5 mm x 120.8 mm
Weight: 180 g
 
Electrical data
Synchronous time monitoring: 1,500 ms (at program 2), 500 ms (at program 4 and 5)
Protection class: EN 61140
Type of supply voltage: PELV (electrical output circuit on UE410-4RO/UE410-2RO > 25 V AC/60 V DC), PELV or SELV (electrical output circuit on UE410-4RO/UE410-2RO < 25 V AC/60 V DC)
Supply voltage: 24 V DC (19.2 V DC ... 30 V DC)
Ripple: ≤ 3 V
Power consumption: 3 W
Short-circuit protection: 4 A gG
Switch-on time: 60 s
Switch-on time of inputs: 70 ms
Input voltage HIGH: 13 V DC ... 30 V DC
Input voltage LOW: -5 V DC ... 5 V DC
Input current HIGH: 2.4 mA ... 3.8 mA
Input current LOW: -2.5 mA ... 2.1 mA
Output voltage: 18 V DC ... 30 V DC
Output current: 2 A
Muting time to operate: 61 ms, at program 3 1)
Tolerated muting sensor signal interrupt: 100 ms, at program 3 2)
Switch-on time ENTER button: 3 s Upon applying the supply voltage
Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored
Response time: ≤ 13 ms≤ 79 ms 3)
Number of inputs: 2 dual-channel or 4 single-channel
Number of outputs: 2 dual-channel or 4 single-channel
Number of muting sensors: 0, 2
1) Time between valid muting condition and active muting  2) One muting input may be LOW for this time  3) Depending on the selected program and the connected sensors  
Interfaces
Connection type: Cable gland
 
Ambient data
Connection type: Plug-in screw-type terminals
Enclosure rating terminals: IP 20
Protection class housing: IP 40
Ambient operating temperature: -25 °C ... 55 °C
Storage temperature: -25 °C ... 70 °C
Air humidity: 15 % ... 95 %, non-condensing
Climate conditions according to: EN 61131-2
Electromagnetic compatibility (EMC): EN 61000
EN 55011
Vibration resistance: 5 g, 5 Hz ... 500 Hz (EN 60068-2-6)
 
Products specifications
Manufacturer category Sick UE100
Manufacturer Sick