Select Store:
Select Currency:

Sick UE410-XM4 (6034646)

Product Summary

UE410-XM4 SAFETY-UNIT
Manufacturer: Sick
Manufacturer part number: 6034646
SKU: 183072
Weight(kg): 0.2420

Click here to check availability

Pricing - Condition Manufacturer New

£227.21 excl VAT
£215.85 excl VAT

Downloads

  • Two different types: in-/output expansion modules and input expansion modules
  • Two variants per type : module for common applications and an expert module for muting
  • Modularly expandable
  • 6 inputs, 4 outputs or 8 inputs
  • Small width of 22.5 mm
  • Pluggable terminals for a fast module replacement
  • PNP outputs, each up to 2A
  • Your benefits

  • Only one configuration for the complete system, simplifying commissioning
  • Rich diagnostic functions available via Fieldbus gateway module
  • Easy to expand if more inputs are required
  • Easy diagnostics via clear LED status indicators
  • Use of powerful PNP semiconductor outputs allows to remove relays

Safety-related parameters
Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061)
Category:Category 4 (EN ISO 13849)
Performance level:PL e (EN ISO 13849)
PFHd:7.9 * 1E-09
TM (mission time):20 a
Functions
Number of reset-/restart inputs:1
Number of external device monitoring:1
Muting:
Override:
Belt stop:-
Concurrence monitoring:
Monitoring total muting time:
Sensor gap monitoring:
End of muting by ESPE:
Mechanical data
Dimensions (W x H x D):22.5 mm x 96.5 mm x 120.8 mm
Weight:180 g
Electrical data
Protection class:EN 61140
Type of supply voltage:PELV (electrical output circuit on UE410-4RO/UE410-2RO > 25 V AC/60 V DC), PELV or SELV (electrical output circuit on UE410-4RO/UE410-2RO < 25 V AC/60 V DC)
Supply voltage:24 V DC (19.2 V DC ... 30 V DC)
Ripple:≤ 3 V
Power consumption:3 W
Short-circuit protection:4 A gG
Switch-on time:10 s
Switch-on time of inputs:70 ms
Input voltage HIGH:15 V DC ... 30 V DC
Input voltage LOW:-5 V DC ... 5 V DC
Input current HIGH:2.3 mA ... 3 mA3.6 mA
Input current LOW:-2.5 mA ... 0.15 mA
Output voltage:18 V DC ... 30 V DC
Output current:2 A
Muting time to operate:70 ms
Tolerated muting sensor signal interrupt:200 ms 1)
Total muting monitoring time:Activation and time adjustable 0.33 ... 60 min
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Response time:≤ < 13 ms
Number of inputs:1 dual-channel and 4 single-channel
Number of outputs:1 dual-channel and 2 single-channel
Number of muting sensors:2, 4
1) One muting input may be LOW for this time  
Interfaces
Connection type:Cable gland
Ambient data
Connection type:Plug-in spring terminals
Enclosure rating terminals:IP 20
Protection class housing:IP 40
Ambient operating temperature:-25 °C ... 55 °C
Storage temperature:-25 °C ... 70 °C
Air humidity:15 % ... 95 %, non-condensing
Climate conditions according to:EN 61131-2
Electromagnetic compatibility (EMC):EN 61000
EN 55011
Vibration resistance:5 g, 5 Hz ... 500 Hz (EN 60068-2-6)
Products specifications
Manufacturer category Sick UE100
Manufacturer Sick