  • Two different types: in-/output expansion modules and input expansion modules
  • Two variants per type : module for common applications and an expert module for muting
  • Modularly expandable
  • 6 inputs, 4 outputs or 8 inputs
  • Small width of 22.5 mm
  • Pluggable terminals for a fast module replacement
  • PNP outputs, each up to 2A
  • Your benefits

  • Only one configuration for the complete system, simplifying commissioning
  • Rich diagnostic functions available via Fieldbus gateway module
  • Easy to expand if more inputs are required
  • Easy diagnostics via clear LED status indicators
  • Use of powerful PNP semiconductor outputs allows to remove relays

Safety-related parameters
Safety integrity level:SIL3 (IEC 61508)
Category:Category 4 (EN ISO 13849)
Performance level:PL e (EN ISO 13849)
PFHd:2.5 * 1E-09
6.0 * 10-9
TM (mission time):20 a
Stop category:0 (EN 60204)
Functions
Number of reset-/restart inputs:2
Number of external device monitoring:2
Muting:
Mechanical data
Dimensions (W x H x D):22.5 mm x 96.5 mm x 120.8 mm
Weight:180 g
Electrical data
Synchronous time monitoring:1,500 ms (at program 2), 500 ms (at program 4 and 5)
Protection class:EN 61140
Type of supply voltage:PELV (electrical output circuit on UE410-4RO/UE410-2RO > 25 V AC/60 V DC), PELV or SELV (electrical output circuit on UE410-4RO/UE410-2RO < 25 V AC/60 V DC)
Supply voltage:24 V DC (19.2 V DC ... 30 V DC)
Ripple:≤ 3 V
Power consumption:3 W
Short-circuit protection:4 A gG
Switch-on time:60 s
Switch-on time of inputs:70 ms
Input voltage HIGH:13 V DC ... 30 V DC
Input voltage LOW:-5 V DC ... 5 V DC
Input current HIGH:2.4 mA ... 3.8 mA
Input current LOW:-2.5 mA ... 2.1 mA
Output voltage:18 V DC ... 30 V DC
Output current:2 A
Muting time to operate:61 ms, at program 3 1)
Tolerated muting sensor signal interrupt:100 ms, at program 3 2)
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Response time:≤ 13 ms≤ 79 ms 3)
Number of inputs:2 dual-channel or 4 single-channel
Number of outputs:2 dual-channel or 4 single-channel
Number of muting sensors:0, 2
1) Time between valid muting condition and active muting  2) One muting input may be LOW for this time  3) Depending on the selected program and the connected sensors  
Interfaces
Connection type:Cable gland
Ambient data
Connection type:Plug-in screw-type terminals
Enclosure rating terminals:IP 20
Protection class housing:IP 40
Ambient operating temperature:-25 °C ... 55 °C
Storage temperature:-25 °C ... 70 °C
Air humidity:15 % ... 95 %, non-condensing
Climate conditions according to:EN 61131-2
Electromagnetic compatibility (EMC):EN 61000
EN 55011
Vibration resistance:5 g, 5 Hz ... 500 Hz (EN 60068-2-6)
Products specifications
Manufacturer category Sick UE4100
Manufacturer Sick