Applications | Safety command devices: | |
Electro-mechanical safety switches: | |
Non-contact safety switches: | |
Opto-electronic protective devices: | |
Two-hand control systems: | |
Operating mode selector switch: | |
Muting sensors: | |
Muting lamp: | |
|
Functions |
Safe device communication via EFI/SDL: | - |
External device monitoring: | |
Reset/restart: | Manual / automatic / configurable |
Logical functions: | AND, NOT, OR, XNOR, XOR |
On-delay: | |
Off-delay: | |
Door monitoring: | |
Signal routing: | |
|
Technical data |
Enclosure rating: | IP 67 |
Ambient operating temperature from ... to: | -10 °C ... 55 °C |
Protection class: | III (EN 61140) |
Safety integrity level: | SIL3 (IEC 61508) |
Category: | Category 4 (EN 954-1) |
Maximum power consumption: | 4 A, per connection 1) |
Connection type supply voltage: | Mini 7/8" × 4 |
Number of safety inputs: | 6 dual-channel or 12 single-channel |
Input voltage HIGH field signal inputs: | 11 V DC ... 30 V DC |
Input delay field signal inputs: | Configurable 0 ... 635 ms |
Number of test/signal outputs (with current monitoring): | 12 |
Type of output test/signal outputs: | PNP semiconductor |
Output current test/signal outputs: | 700 mA |
Number of safe outputs: | 2 dual-channel |
Type of output safety capable outputs: | Bipolar type |
Maximum switching current safety capable outputs: | 2 A |
Maximum number of safety target connections: | 6 |
DeviceNet communication rate: | 125 kbit/s, 250 kbit/s, 500 kbit/s, Autobaud detection |
Connection type DeviceNet: | Mini 7/8" × 5 |
System part: | Network solutions |
|
Electrical data |
Fieldbus: | DeviceNet Safety |
Supply voltage: | 19.2 V DC ... 28.8 V DC |
|
Ambient data |
Weight: | 570 g |
|