Hazardous point protection: |
|
Hazardous area protection: |
|
Technical data |
Enclosure rating: |
IP 54 (IEC 60529) |
Protection class: |
III (EN 50178) |
Type: |
Type 2 (IEC 61496) |
Safety integrity level: |
SIL1 (IEC 61508), SILCL1 (EN 62061) |
Category: |
Category 2 (EN ISO 13849) |
Test rate (internal test): |
50 /s (EN ISO 13849) |
Maximum demand rate: |
30 /min (EN ISO 13849) 1) |
Performance level: |
PL c (EN ISO 13849) |
PFHd: |
3.2 * 1E-09 |
TM (mission time): |
20 a |
Maximum protective field range: |
2.12 m 2) |
Minimum protective field size: |
40 cm x 40 cm 3) |
Maximum protective field size: |
150 cm x 150 cm 4) |
Aspect ratio protective field: |
1:1 to 2:1 |
Resolution: |
20 mm, 24 mm, 30 mm 5) |
Wavelength illumination: |
850 nm |
Supply voltage: |
24 V DC |
Number of external device monitoring inputs: |
1 |
Number of restart interlock inputs: |
1 |
Number of teach/sync inputs: |
1 |
Switching outputs: |
2 |
Power consumption: |
165 mA, 690 mA 6) 7) |
Switching current: |
6 mA ... 250 mA |
Response time: |
20 ms |
Connection type: |
M12 x 8 |
Dimensions (W x H x D): |
90 mm x 50 mm x 90 mm |
Ambient operating temperature from ... to: |
0 °C ... 50 °C |